SUN VALLEY STOVE COMPANY
CAST IRON STOVE AND BURNER SYSTEM
OPERATING STOVE WITH
Continued
OPTIONAL REMOTE
OPERATION
Note: All remote control accessories must be purchased separately (See Accessories on page 27). Follow instructions included with the remote control.
Selector Switch in Remote
Position (GHRC Optional
Remote Control)Control Knob in
On Position
| LO H |
| ON |
| I |
|
|
REMOTE OFF ON |
| T |
|
| L |
| |
|
| O | OFF |
|
| I | |
|
| P |
|
Flame Adjustment Knob
Figure 51 - Setting the (GHRC) Remote Control Selector Switch, Valve Control Knob, and Flame Adjustment Knob for Remote Operation
• In the ON mode, the burners will |
ignite. The heater is in manual |
mode when ON is lit. |
• In the AUTO mode, the thermostat |
in the |
trols the room temperature. To in- |
crease the room temperature, press |
the top arrow of the TEMP button. |
To lower the room temperature, |
press the bottom arrow of the |
TEMP button. At higher settings |
the heater will run longer. |
IMPORTANT: This remote control |
has been specially engineered to |
Thermostat Control Operation
(Optional GHRCTA Only) The thermo- stat control setting on the remote control unit can be set to any comfort level be- tween WARMER and COOLER. The burners will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by
Selector Switch in
Remote Position
(GHRCTA Optional
Remote Control)
ON
OFF
REMOTE
Control Knob in On Position
O | H |
|
|
L |
| ON | |
| I |
|
|
|
| T |
|
|
| O | OFF |
|
| L |
|
|
| I |
|
|
| P |
|
take an air temperature sample ev- |
ery 5.5 minutes in the auto mode. |
It will not respond immediately to |
the temperature setting being |
turned up or down. |
IMPORTANT: The |
mote control unit must be near the |
heater. Do not keep the |
remote control unit too close to the |
household depending upon the amount of space to be heated, the output of the cen- tral heating system, etc.
NOTICE: You must light the pilot before using the
1.After lighting, let pilot flame burn for about one minute. Turn control knob on the control valve to ON position. Turn flame adjustment knob any- where between HI and LO. Slide the selector switch to the REMOTE posi- tion. Note: The burners may light if
IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery.
IMPORTANT: Be sure to press the ON/OFF buttons on the
Flame Adjustment Knob
Figure 52 - Setting the (GHRCTA) Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
GHRC Series Operation:
2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.
GHRCTA Series Operation:
2b. Press the AUTO/ON/OFF button on the
Shows Temperature Setting
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected
heater. The thermostat on the |
heat up too quickly and turn the |
heater off. |
3. To turn the burner off, press the |
AUTO/ON/OFF button until OFF |
lights. The pilot will remain lit. |
IMPORTANT: To turn the pilot off, |
manually turn the control knob on the |
heater to the OFF position. |
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burner On or Off and Allows You to Choose the Auto Setting
Figure 53 -
For more information, visit www.desatech.com | 20 | 106706 |