Desa MSRBVP Stove And B-Vent, Burner System, Installation, Continued, Control Valve Terminals

Models: MSRBVP MSRBVN

1 32
Download 32 pages 40.7 Kb
Page 15
Image 15
STOVE AND B-VENT

OWNER’S MANUAL

STOVE AND B-VENT

 

BURNER SYSTEM

 

INSTALLATION

 

Continued

 

Equipment

Propane/LP

Shutoff

Supply Tank

Valve

 

Gas Valve

 

Figure 34 - Checking Gas Joints for Propane/LP Gas Burner System

Equipment

Shutoff Valve

Gas Meter

Gas Valve

Figure 35 - Checking Gas Joints for Natural Gas Burner System

INSTALLING OPTIONAL WALL MOUNTED SWITCH GWMS2

1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 36. If wires are not connected as shown, the switch will not work.

2.Route the 25 ft. wire through openings provided on the sides of the burner sys- tem to a convenient location to mount your switch.

3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.

4.Install the wall switch and cover in the wall.

To Control

Switch or

Optional

Accessory

Figure 36 - Control Valve Terminals

Continued

106706