OWNER’S MANUAL
STOVE AND |
| |
BURNER SYSTEM |
| |
INSTALLATION |
| |
Continued |
| |
Equipment | Propane/LP | |
Shutoff | ||
Supply Tank | ||
Valve | ||
| ||
Gas Valve |
|
Figure 34 - Checking Gas Joints for Propane/LP Gas Burner System
Equipment |
Shutoff Valve |
Gas Meter |
Gas Valve |
Figure 35 - Checking Gas Joints for Natural Gas Burner System
INSTALLING OPTIONAL WALL MOUNTED SWITCH GWMS2
1.Connect one terminal of 25 ft. wire for the wall switch to the TPTH terminal on the valve. Connect remaining wire terminal to the TH terminal on the valve. Make sure that the wire terminals are in the positions on the unit as pictured in Figure 36. If wires are not connected as shown, the switch will not work.
2.Route the 25 ft. wire through openings provided on the sides of the burner sys- tem to a convenient location to mount your switch.
3.Connect one bare wire end to each of the terminals of the GWMS2 wall switch.
4.Install the wall switch and cover in the wall.
To Control
Switch or
Optional
Accessory
Figure 36 - Control Valve Terminals
Continued
106706 | 15 | For more information, visit www.desatech.com |