Vertical Termination Configurations

14

VENTING INSTALLATION INSTRUCTIONS

Installation for Vertical Termination (Cont.)

VENTING INSTALLATION INSTRUCTIONS

Continued

Vertical Termination Configurations

Figures 21 through 24 show four different configurations for verti- cal termination.

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

45° Elbow

Note: Install

restrictor into inner

 

collar of fireplace

 

as shown.

Venting with One 90° Elbow

Vertical (V)

Horizontal (H)

5' min.

2' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

20' max.

8' max.

45° Elbow

Note: Install

restrictor into inner

 

 

collar of fireplace

 

as shown.

Figure 22 - Vertical Venting Configuration Using One 90° Elbow

(Vertical Round High Wind Termination Shown)

Venting with Two 90° Elbows

Vertical (V1)

Horizontal (H)

5' min.

6' max.

6' min.

12' max.

7' min.

18' max.

8' min.

20' max.

Figure 21 - Vertical Venting Configuration Using Two 90° Elbows with Two Horizontal Runs (Vertical Round High Wind Termination Shown)

Note: Install restrictor into inner collar of Venting with One 90° Elbow fireplace as shown.

45° Elbow

Note: Vertical (V1) + Vertical (V2) = 40' max.

Figure 23 - Vertical Venting Configuration Using Two 90° Elbows

(Vertical Round High Wind Termination Shown)

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111252-01E

Page 14
Image 14
Desa (V)V36N-B SERIES, VV36NC1 SERIES Vertical Termination Configurations, Venting Installation Instructions, Continued

FAQ

What are the venting installation instructions for Indoor Fireplace?

The venting installation instructions for Indoor Fireplace include vertical termination configurations, venting with one or two 90 elbows, high wind termination, and more.

How many 90 elbows are needed for vertical venting?

For vertical venting, you can use either one or two 90 elbows, depending on your specific installation requirements.

What is a high wind termination and when is it used?

A high wind termination is used for venting in high wind conditions and is recommended for specific configurations. It helps ensure proper venting performance even in windy conditions.