Desa CHDV36NR-C Venting Installation Instructions, Continued, Installing Horizontal Vent Cap

Models: (V)V36P-B SERIES, VV36PC1 SERIES CHDV36NR-C (V)V36N-B SERIES, VV36NC1 SERIES

1 40
Download 40 pages 55.19 Kb
Page 9
Image 9
Figure 10 - Installing Horizontal Vent Cap

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

9

VENTING INSTALLATION INSTRUCTIONS

Continued

(Noncombustible Exterior) WARNING: Do not recess vent termination into any wall. This will cause a fire hazard.

6.Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 1/2" round hole and attach to the exte- rior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around the outside edges to make a seal be- tween it and the outside wall. Note: The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings.

Combustible Exterior Wall: For vinyl siding, stucco, or wood exteriors, a siding standoff may be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging the siding materials. Siding material must be cut to accommodate standoff. Bolt the vent cap to the stand- off. Apply non-hardening mastic around outside edge of stand- off. Position the standoff/cap assembly in the center of the 10 3/4" square hole and attach to exterior wall with wood screws provided (see Figure 11). The siding standoff must sit flush against the exterior fascia material.

7.Combustible Exterior Wall Only: Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap (see Figure 12).

8.Carefully move fireplace, with vent assembly attached, toward wall and insert vent pipe into horizontal termination. The pipe overlap should be a minimum of 11/4".

Vent Cap

Wood Screw

Figure 10 - Installing Horizontal Vent Cap

(Noncombustible Exterior)

Cut Siding Away to Fit Standoff

Standoff

Wood Screw

Manual backgroundVent Cap

Screws

Apply Mastic

to All Four Sides

Figure 11 - Installing Siding Standoff (Combustible Exterior Wall)

Interior Wall

Manual backgroundSurface

Wall

Manual background Firestop

Vent Cap

Horizontal

(Horizontal

Vent Pipe

Termination)

 

Screw

Figure 12 - Connecting Vent Cap with Horizontal Vent Pipe

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

111252-01E

Page 9
Image 9
Desa CHDV36NR-C Venting Installation Instructions, Continued, Installing Horizontal Vent Cap, Noncombustible Exterior

FAQ

What are the instructions for positioning the horizontal vent cap?

Position the horizontal vent cap in the center of the round hole and attach to the exterior wall with provided wood screws. Apply non-hardening mastic sealant for a secure seal.

How should the vent cap be attached to combustible exterior walls?

For vinyl siding, stucco, or wood exteriors, install a siding standoff between the vent cap and exterior wall to prevent heat damage. Bolt the vent cap to the standoff and apply non-hardening mastic around the outside edge.

What should be done before connecting the horizontal run to the vent cap?

Slide the wall firestop over the vent pipe for combustible exterior walls to ensure proper installation.