CHECKING GAS CONNECTIONS

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Installing Gas Piping To Stove/Burner System Location (Cont.) Connecting Stove/Burner System To Gas Supply Checking Gas Connections

19

STOVE AND DIRECT-VENT BURNER SYSTEM INSTALLATION

Continued

We recommend that you install a sediment trap in supply line as shown in Figure 38. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into burner system gas controls. If sediment trap is not installed or is installed wrong, burner system may not run properly.

CSA Design-Certified Equipment

Shutoff Valve with 1/8" NPT Tap*

Equipment Shutoff Valve

To Flare Fitting on Control Valve

Flexible Gas Line from Equipment Shutoff Valve

Provided by Installer

Natural - To Gas Supply Propane/LP - To External Regulator

Approved Flexible

Gas Line

3" Minimum CONNECTING STOVE/BURNER SYSTEM TO GAS SUPPLY

Propane/LP - From External Regulator (11" W.C. to 14"

W.C. Pressure)

Natural - From Gas Meter (5" W.C. to 10.5" W.C. Pressure)

Figure 39 - Flexible Gas Line

CHECKING GAS CONNECTIONS

Pressure Testing Gas Supply Piping System WARNING: Test all gas piping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

Manual background WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection solution

Cap Pipe Tee

Nipple Joint

Sediment Trap

Figure 38 - Gas Connection

*The CSA design-certified equipment shutoff valve may be sup- plied with the appliance or you can purchase it from your dealer.

CONNECTING STOVE/BURNER SYSTEM TO GAS SUPPLY

Installation Items Needed

5/16" hex socket wrench or nut-driver

sealant (resistant to propane/LP gas, not provided)

1.Open lower door panel.

2.Route flexible gas line (provided by installer) from equipment shutoff valve to burner system. Route flexible gas supply line through slot in stove bottom and attach to valve.

3.Check all gas connections for leaks. See Checking Gas Con- nections.

to all gas joints. Bubbles forming show a leak. Cor- rect all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect burner system and its individual equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage burner system gas regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas burner system or open- ing main gas valve located on or near gas meter for natural gas burner system, or using compressed air.

4.Check all joints of gas supply piping system. Apply a noncor- rosive leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Reconnect burner system and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Manual backgroundFor moreManual backgroundManual backgroundManual backgroundvisit www.Manual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background