CGHRC Series Operation:

OPERATING STOVE WITH BURNER SYSTEM

Continued

CGHRC Series Operation:

OPERATING STOVE WITH BURNER SYSTEM

25

Optional Remote Operation (Cont.)

Operating Optional Blower Accessory

 

 

 

2a. Press the ON/OFF button to turn the burners on and off. When turning burners off, the pilot will remain lit.

CGHRCTA Series Operation:

2b. Press the AUTO/ON/OFF button on the hand-held remote control (see Figure 57). The lights to the left of the button will show AUTO, ON, or OFF.

• In the ON mode, the burners will ignite. The heater is in

manual mode when ON is lit.

• In the AUTO mode, the thermostat in the hand-held re-

mote unit controls the room temperature. To increase the

room temperature, press the top arrow of the TEMP but-

ton. To lower the room temperature, press the bottom

arrow of the TEMP button. At higher settings the heater

Shows

Temperature

Setting

The Log Heater will Automatically

Cycle between CGHRCTA Series Operation:OPERATING OPTIONALManual background Pilot and the Heat Manual backgroundManual backgroundManual background Setting that has

been Selected

Increases Room

Temperature in

AUTO Mode

Decreases Room

Manual background Temperature in

AUTO Mode

Turns Burners On or Off and Allows You to Choose the Auto Setting

will run longer.

IMPORTANT: This remote control has been specially

engineered to take an air temperature sample every 5.5

minutes in the auto mode. It will not respond immedi-

ately to the temperature setting being turned up or down.

IMPORTANT: The hand-held remote control unit must

be near the heater. Do not keep the hand-held remote

control unit too close to the heater. The thermostat on

the hand-held remote control unit will heat up too quickly

and turn the fireplace off.

3. To turn the burner off, press the AUTO/ON/OFF button

until OFF lights. The pilot will remain lit.

IMPORTANT: To turn the pilot off, manually turn the con-

trol knob on the heater to the OFF position.

Selector Switch in Remote

Gas Control Knob

Variable

Position (Optional Remote

in On Position

Control Knob

Control)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LO

IN OUT

Figure 56 - Setting the Selector Switch, Gas Control Knob, and Variable Control Knob for Remote Operation

Figure 57 - Hand-Held Thermostat Remote Control Unit Selections (CGHRCTA Only)

OPERATING OPTIONAL

BLOWER ACCESSORY

Locate the blower controls by opening the lower door on the stove. Blower controls are located on the left side of the switch bracket to the left just inside the door.

Both the GA3700 manual blower and the DA3610T thermo- statically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

Note for DA3610T Only: If you are using DA3610T blower with optional thermostat (wall mount or remote control) for the burner system, your burner system and blower will not turn on and off at the same time. The burner system may run for several minutes before the blower turns on. After the burner system modulates to the pilot position, the blower will continue to run. The blower will shut off after the burner system temperature decreases.

The blower helps distribute heated air from the burner system. Periodically check the air passageways of the burner system and remove any dust, dirt, or other obstructions that will hinder the flow of air.