Desa Tech CDVBNC Continued, To Turn Off Gas To Appliance, Manual Lighting Procedure, For..com

Models: CDVBPC CDVBNC

1 40
Download 40 pages 37.98 Kb
Page 24
Image 24
TO TURN OFF GAS

24

OPERATING STOVE WITH BURNER SYSTEM

LIghting Instructions (Cont.)

To Turn Gas Off To Appliance

Manual Lighting Procedure

Optional Remote Operation

OPERATING STOVE WITH BURNER SYSTEM

Continued

9.Push in gas control knob all the way and hold. Immedi- ately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8, page 23.

If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

10.Turn gas control knob counterclockwise Shutting Off Burners Only (pilot stays lit) to “ON”.

11.Turn on all electric power to the burner system.

12.Turn the ON/OFF switch to ON position.

13.This valve is equipped with a HI/LO feature. Set burner system input as desired.

14.Close lower panel.

TO TURN OFF GAS

TO APPLIANCE

1.Open lower panel.

2a. Turn ON/OFF switch to “OFF”.

2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to the appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise MANUAL LIGHTING to “OFF”.

5.Close lower panel.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

1.Turn gas control knob clockwise OPTIONAL REMOTE to the PILOT position.

2.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, pages 21 and 22).

2.Follow steps 1 through 8 under Lighting Instructions, page 23.

3.Depress gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after light- ing pilot. After 30 seconds, release gas control knob. Now follow steps 10 through 14, column 1.

5.Replace glass door (see Removing/Replacing Glass Door, pages 21 and 22).

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased sepa- rately (see Accessories, page 36). Follow instructions included with the remote control.

Thermostat Control Operation

(Optional CGHRCTA Only) The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instruc- tions, pages 23 and 24.

1. After lighting, let pilot flame burn for about one minute.

Turn gas control knob on the control valve to ON position.

Turn variable control knob anywhere between HI and LO.

Slide the selector switch to the REMOTE position. Note:

The burners may light if hand-held remote ON button was

on when selector switch was last turned off. You can now

turn the burners on and off with either optional hand-held

remote control unit.

Piezo

Gas Control Knob

Ignitor

 

 

 

ILO

 

P

T

 

F

O

 

F

N

 

O

 

IN

OUT

Variable

Control Knob

 

 

OT

 

P

IL

 

 

IH

 

TH

 

 

LO

 

TP

 

 

TPTH

IMPORTANT: Do not leave the selector switch in the RE-

MOTE position when the pilot is not lit. This will drain the

battery.

IMPORTANT: Be sure to press the ON/OFF buttons on the

hand-held remote control unit for up to 3 seconds to assure

proper operation.

Figure 55 - Control Valve

Thermostat Control OperationManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

105501-01G

Page 24
Image 24
Desa Tech CDVBNC Continued, To Turn Off Gas To Appliance, Manual Lighting Procedure, Optional Remote Operation, For..com