Desa Tech CDVBNC, CDVBPC manual Continued, Installing Optional Blower Accessory, For..com

Models: CDVBPC CDVBNC

1 40
Download 40 pages 37.98 Kb
Page 8
Image 8
INSTALLING OPTIONAL BLOWER

8

CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLY

Installing Optional Blower Accessory

CAST IRON STOVE AND DIRECT-VENT BURNER SYSTEM ASSEMBLY

Continued

INSTALLING OPTIONAL BLOWER

ACCESSORY

NOTICE: If installing blower in an existing stove with burner system with gas connections, shut off gas supply and disconnect burner system from gas sup- ply. Contact a qualified service person to do this.

Attaching Thermal Switch to CDA3620T Thermostatically- Controlled Blower

When installing the CDA3620T thermostatically-controlled blower accessory, you must first secure the thermal switch to the blower.

1.Remove the two hex head screws on the blower assembly as shown in Figure 14.

2.Place the green wire between the bottom hole on the thermal switch bracket and the bottom hole on the blower assembly. Insert one of the hex screws into all three pieces and tighten.

3.Insert the top screw through the thermal switch bracket and into the blower assembly. Tighten screw.

4.Connect the blue wire on the blower assembly to the right side of the thermal switch.

5.Connect the black wire to the left side of the thermal switch.

Black Wire

White Wire

Blower

 

 

 

Assembly

Thermal

 

 

Switch with

 

 

Bracket

 

 

Hex Head

 

Green

 

Wire

Screws

Blue Wire

 

 

 

Figure 14 - Attaching Thermal Switch to CDA3620T Thermostatically-Controlled Blower Accessory

Installing GA3750/CDA3620T Blowers

1.Align the holes in the top mounting tabs of blower with holes in wall of rear cover (see Figure 15). Using the 4 screws pro- vided, mount blower and tighten screws securely.

Note: For CDA3620T, make sure the thermal switch has been properly installed to fit against the back of the burner system.

2.Make sure all wire connections to terminals on blower motor (and thermal switch where applicable) are securely attached and that the screw retaining the green ground wire is tight.

3.Place speed control on back wall inside of rear cover and push the plastic control shaft through opening (see Figure 15).

4.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until tight against the side of rear cover. Place control knob provided onto shaft (see Figure 15).

5.Plug in blower power cord.

6.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by rotating knob fully counterclockwise before continuing.

Installing GA3750/CDA3620T Blowers WARNING: Never touch the blower wheel while in operation.

7.Peel off the backing paper and stick the supplied wiring diagram decal on the inside of rear cover on right side opposite control.

Blower

Speed Control

 

Control

 

Mounting

Knob Lock

Control Shaft

Screws

Nut

Power

(Included in

 

Cord

Hardware

 

 

Pack)

White

Black

Wiring

Wire

Wire

Diagram

 

 

Decal

 

 

Rear

 

 

Cover

Blue

Green

 

Wire

Blower

 

Ground Wire

Figure 15 - Installing Optional Blower Accessory (Thermostat Model CDA3610T Shown)

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

105501-01G

Page 8
Image 8
Desa Tech CDVBNC, CDVBPC Continued, Installing Optional Blower Accessory, For..com, Installing GA3750/CDA3620T Blowers