female receptacle of the cord set must meet IEC-60320 requirements and may look like (Figure A1 below):

For the United States and Canada

In the United States and Canada, the male plug is a NEMA5-15 style (Figure A2), UL Listed, and CSA Labeled. For units that are mounted on a desk or table, type SVT or SJT cord sets may be used. For units that sit on the floor, only SJT type cord sets may be used. The cord set must be selected according to the current rating for your unit. Please consult the table below for the selection criteria for power cords used in the United States and Canada.

Code Type

Size of Conductors in Cord

Maximum Current Rating

 

 

of Unit

SJT

18 AWG

10 Amps

 

16 AWG

12 Amps

 

14 AWG

12 Amps

SVT

18 AWG

10 Amps

 

17 AWG

12 Amps

For European Countries

In Europe, you must use a cord set which is appropriate for the receptacles in your country. The cord set is HAR-certified, and includes a special mark that appears on the outer sheath or on the insulation of one of the inner conductors.

For The United Kingdom

For your safety please read the following text carefully. If the fitted molded plug is unsuitable for the socket outlet, then the plug should be cut off and disposed of safely. There is a danger of severe electrical shock if the cut off plug is inserted into an appropriate socket. If a new plug is to be fitted, please observe the wiring code as shown below. Please consult a qualified electrician if you have any questions.