Dukane 8912-RJ, 8755G-RJ user manual RS-232C communication command table, continued on next page

Models: 8755G-RJ 8912-RJ

1 128
Download 128 pages 1.87 Kb
Page 110
Image 110
RS-232C communication command table

RS-232C Communication (continued)

RS-232C communication command table

Names 

 

Operation Type

 

 

 

Header

 

 

 

 

 

 

 

 

 

 

Command Data

 

 

 

 

 

 

 

 

CRC

 

 

Action

 

Type

 

Setting Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

Set

Turn off

BE EF

 

03

06 00

 

 

 

2A

D3

 

 

01 00

 

00 60

 

00 00

 

 

Turn on

BE EF

 

03

06 00

 

 

 

BA D2

 

 

01 00

 

00 60

 

01 00

 

 

Get

BE EF

 

03

06 00

 

 

 

19 D3

 

 

02 00

 

00 60

 

00 00

 

 

 

[Example return] 

01

00

 

 

 

 

02

00 

 

 

 

 

 

 

 

 

00

00

 

 

 

 

 

 

 

 

 

 

 

 

[Off]

[On]

 

 

 

[Cool down]

 

 

 

 

Input Source

Set

COMPUTER1

BE EF

 

03

06 00

 

 

 

FE D2

 

 

01 00

 

00 20

 

00 00

 

 

COMPUTER2

BE EF

 

03

06 00

 

 

 

3E

D0

 

 

01 00

 

00 20

 

04 00

 

 

COMPONENT

BE EF

 

03

06 00

 

 

 

AE D1

 

 

01 00

 

00 20

 

05 00

 

 

S-VIDEO

BE EF

 

03

06 00

 

 

 

9E

D3

 

 

01 00

 

00 20

 

02 00

 

 

VIDEO

BE EF

 

03

06 00

 

 

 

6E

D3

 

 

01 00

 

00 20

 

01 00

 

 

Get

BE EF

 

03

06 00

 

 

 

CD D2

 

 

02 00

 

00 20

 

00 00

Error Status

 

Get

BE EF

 

03

06 00

 

 

 

D9

D8

 

 

02 00

 

20 60

 

00 00

 

 

 

[Example return] 

01

00

 

 

 

 

02

00

 

 

03

00 

 

 

 

 

00

00

 

 

 

 

 

 

 

 

 

 

[Normal]

[Cover error]

 

 

[Fan error]

 

[Lamp error] 

 

 

 

 

04

00

05

00

 

 

 

 

06

00

 

 

07

00 

 

 

 

[Temp error]

[Air flow error]

 

[Lamp time error]

 

[Cold error] 

 

 

 

 

08 00

09 00

 

 

 

 

10 00 

 

 

 

 

 

 

 

[Filter error]

(Filter missing error) (Inner Sencer error)

 

 

 

BRIGHTNESS

 

Get

BE EF

 

03

06 00

 

 

 

89 D2

 

 

02 00

 

03 20

 

00 00

 

 

Increment

BE EF

 

03

06 00

 

 

 

EF D2

 

 

04 00

 

03 20

 

00 00

 

 

Decrement

BE EF

 

03

06 00

 

 

 

3E

D3

 

 

05 00

 

03 20

 

00 00

BRIGHTNESS Reset

 

Execute

BE EF

 

03

06 00

 

 

 

58 D3

 

 

06 00

 

00 70

 

00 00

CONTRAST

 

Get

BE EF

 

03

06 00

 

 

 

FD D3

 

 

02 00

 

04 20

 

00 00

 

 

Increment

BE EF

 

03

06 00

 

 

 

9B

D3

 

 

04 00

 

04 20

 

00 00

 

 

Decrement

BE EF

 

03

06 00

 

 

 

4A

D2

 

 

05 00

 

04 20

 

00 00

CONTRAST Reset

 

Execute

BE EF

 

03

06 00

 

 

 

A4

D2

 

 

06 00

 

01 70

 

00 00

PICTURE MODE

Set

NORMAL

BE EF

 

03

06 00

 

 

 

23

F6

 

 

01 00

 

BA 30

 

00 00

 

 

CINEMA

BE EF

 

03

06 00

 

 

 

B3 F7

 

 

01 00

 

BA 30

 

01 00

 

 

DYNAMIC

BE EF

 

03

06 00

 

 

 

E3 F4

 

 

01 00

 

BA 30

 

04 00

 

 

BOARD(BLACK)

BE EF

 

03

06 00

 

 

 

E3

EF

 

 

01 00

 

BA 30

 

20 00

 

 

BOARD(GREEN)

BE EF

 

03

06 00

 

 

 

73 EE

 

 

01 00

 

BA 30

 

21 00

 

 

WHITEBOARD

BE EF

 

03

06 00

 

 

 

83 EE

 

 

01 00

 

BA 30

 

22 00

 

 

DAYTIME

BE EF

 

03

06 00

 

 

 

E3

C7

 

 

01 00

 

BA 30

 

40 00

 

 

Get

BE EF

 

03

06 00

 

 

 

10

F6

 

 

02 00

 

BA 30

 

00 00

 

 

 

[Example return] 

00

 

04

00

 

10

00

 

 

 

 

 

00

00

01

 

 

 

 

 

 

 

[Normal]

 

[Cinema]

[Dynamic]

[Custom]

 

40 00

 

 

 

 

 

20 00

21 00

 

 

22

00

 

 

 

 

 

 

[BOARD(BLACK) ]

[BOARD(GREEN)]

[WHITEBOARD]

 

[DAY TIME]

GAMMA

Set

#1 DEFAULT

BE EF

 

03

06 00

 

 

 

07 E9

 

 

01 00

 

A1

30

 

20 00

 

 

#1 CUSTOM

BE EF

 

03

06 00

 

 

 

07 FD

 

 

01 00

 

A1

30

 

10 00

 

 

#2 DEFAULT

BE EF

 

03

06 00

 

 

 

97 E8

 

 

01 00

 

A1

30

 

21 00

 

 

#2 CUSTOM

BE EF

 

03

06 00

 

 

 

97 FC

 

 

01 00

 

A1

30

 

11 00

 

 

#3 DEFAULT

BE EF

 

03

06 00

 

 

 

67 E8

 

 

01 00

 

A1

30

 

22 00

 

 

#3 CUSTOM

BE EF

 

03

06 00

 

 

 

67 FC

 

 

01 00

 

A1

30

 

12 00

 

 

#4 DEFAULT

BE EF

 

03

06 00

 

 

 

F7 E9

 

 

01 00

 

A1

30

 

23 00

 

 

#4 CUSTOM

BE EF

 

03

06 00

 

 

 

F7 FD

 

 

01 00

 

A1

30

 

13 00

 

 

#5 DEFAULT

BE EF

 

03

06 00

 

 

 

C7 EB

 

 

01 00

 

A1

30

 

24 00

 

 

#5 CUSTOM

BE EF

 

03

06 00

 

 

 

C7 FF

 

 

01 00

 

A1

30

 

14 00

 

 

#6 DEFAULT

BE EF

 

03

06 00

 

 

 

57 EA

 

 

01 00

 

A1

30

 

25 00

 

 

#6 CUSTOM

BE EF

 

03

06 00

 

 

 

57 FE

 

 

01 00

 

A1

30

 

15 00

 

 

Get

BE EF

 

03

06 00

 

 

 

F4 F0

 

 

02 00

 

A1

30

 

00 00

(continued on next page)

Page 110
Image 110
Dukane 8912-RJ, 8755G-RJ RS-232C communication command table, continued on next page, RS-232C Communication continued