3-7. Mirror

User Manual

3-7. Mirror

Function name:

Mirror Configuration

Function description:

Mirror Configuration is to monitor the traffic of the network. For example, we assume that Port A and Port B are “Mirror To” Port and “Mirror” Port respectively, thus, the traffic passed by Port B will be copied to Port A for monitoring.

Note:

When configuring the mirror function, you should avoid setting a port to be a sniffer port and aggregated port at the same time. It will cause something wrong.

Parameter description:

Enable Mirror:

Used for the activation or de-activation of Port Mirror function. Default is disable.

Monitored Port:

Set up the ports for being monitored. Valid port is Port 1~26 and more than one port is allowed to be chosen at one time.

Monitoring Port:

Set up the port for monitoring. Valid port is Port 1~26. Not Mirrored:

Choose the ports that will not be mirrored.