User Manual

3-9. Rate

Function name:

Rate

Function description:

Rate limit and storm control function is used to set up the limit of Ingress and Egress bandwidth for each port.

Fig. 3-20

Parameter description:

Ingress Rate:

Set up the limit of Ingress bandwidth for the port you choose. Incoming traffic will be discarded if the rate exceeds the value you set up in Data Rate field. Pause frames are also generated if flow control is enabled. Valid range is 64Kbps~80Mbps.

Egress Rate:

Set up the limit of Egress bandwidth for the port you choose. Incoming traffic will be discarded if the rate exceeds the value you set up in Data Rate field. Pause frames are also generated if flow control is enabled. Valid range is 64Kbps~100Mbps.

Publication date: July, 2006

Revision A2

54

Page 60
Image 60
Edimax Technology ES-5224RS+ user manual Rate