Eiki LC-WB40N Appendix Configurations of Terminals, Terminal: Analog RGB Mini D-sub15 pin

Models: LC-WB40N

1 82
Download 82 pages 21.76 Kb
Page 79
Image 79
Appendix

Appendix

Configurations of Terminals

COMPUTER IN 2 /COMPONENT IN /MONITOR OUT (ANALOG)

Terminal: Analog RGB (Mini D-sub 15 pin)

5 4 3 2 1

10 9 8 7 6

15 14 13 12 11

1

Red (R/Cr) Input/Output

9

+5V Power

2

Green (G/Y) Input/Output

10

Ground (Vert.sync.)

3

Blue (B/Cb) Input/Output

11

Ground

4

-----

12

DDC Data

5

Ground (Horiz.sync.)

13

Horiz. sync. Input/Output (Composite H/V sync.)

6

Ground (Red)

14

Vert. sync.

7

Ground (Green)

15

DDC Clock

8

Ground (Blue)

 

 

DVI-I TERMINAL (DIGITAL/ANALOG)

C1 C2

COMPUTER IN 2 /COMPONENT IN /MONITOR OUT (ANALOG) 1 Terminal: Analog RGB (Mini D-sub 15 pin)DVI-I TERMINAL (DIGITAL/ANALOG) 2 USB CONNECTOR (Series B)LAN TERMINAL 3 SERVICE PORT CONNECTOR Terminal : Mini DIN 8-PINManual background 4 Manual backgroundManual background 5 Manual backgroundManual background 6 Manual backgroundManual background 7 Manual backgroundManual background 8 Manual background

Manual background 9 Manual backgroundManual background10Manual backgroundManual background11Manual backgroundManual background12Manual backgroundManual background13Manual backgroundManual background14Manual backgroundManual background15Manual backgroundManual background16Manual backgroundManual background17Manual backgroundManual background18Manual backgroundManual background19Manual backgroundManual background20Manual backgroundManual background21Manual backgroundManual background22Manual backgroundManual background23Manual backgroundManual background24Manual background

C3 C4

C5

C1

Analog Red Input

 

 

 

 

C2

Analog Green Input

 

 

 

 

C3

Analog Blue Input

 

 

 

 

C4

Analog Horiz. sync

 

 

 

 

C5

Analog Ground (R/G/B)

 

 

 

 

1

T.M.D.S. Data2–

9

T.M.D.S. Data1–

17

T.M.D.S. Data0–

2

T.M.D.S. Data2+

10

T.M.D.S. Data1+

18

T.M.D.S. Data0+

3

T.M.D.S. Data2 Shield

11

T.M.D.S. Data1 Shield

19

T.M.D.S. Data0 Shield

4

No Connect

12

No Connect

20

No Connect

5

No Connect

13

No Connect

21

No Connect

6

DDC Clock

14

+5V Power

22

T.M.D.S. Clock Shield

7

DDC Data

15

Ground (for +5V)

23

T.M.D.S. Clock+

8

Analog Vert. sync

16

Hot Plug Detect

24

T.M.D.S. Clock–

USB CONNECTOR (Series B)

2

1

3

4

1

2

3

4

Vcc

-Data + Data Ground

LAN TERMINAL

8 7 6 5 4 3 2 1

1

TX +

5

-----

2

TX –

6

RX –

3

RX +

7

-----

4

-----

8

-----

SERVICE PORT CONNECTOR Terminal : Mini DIN 8-PIN

8

7

6

5

4

3

2

1

 

1

R X D

5

RTS/CTS

2

-----

6

T X D

3

-----

7

GND

4

GND

8

GND

79

Page 79
Image 79
Eiki LC-WB40N Appendix Configurations of Terminals, COMPUTER IN 2 /COMPONENT IN /MONITOR OUT ANALOG, Lan Terminal