Fan control

Setting

Fan

This function provides the following options in the cooling fans’ operation when the projector is turned off (p.23).

L1....... Normal operation

L2....... Slower and lower-sound than the normal operation

(L1), but it takes more time to cool the projector down.

Fan control

Choose the running speed of cooling fans from the following options according to the ground elevation under which you use the projector.

Off.......Normal speed. Set this function to Off when using

the projector in non-high altitude environment.

On 1... Faster than Off mode. Select this mode when using the projector in high altitudes (about 1,200 meters or more above the sea level) where the fans have less cooling effect.

On 2....Faster than On 1 mode. Select this mode when

using the projector in higher altitudes than above where the fans have lesser cooling effect.

On 3....Be sure to set the Lamp control in High and the

Fan control in On 3 when using the projector inclined at between +40 degrees to +140 degrees to the horizontal plane at altitudes between 0 and approximately 1,600 meters above sea level.

Note:

The fan noise becomes louder in On1, On2 and On3.

Setting Fan control to On1, On2 or On3 affects L2 operation in Fan.

Lamp counter

This function is used to display the cumulative lamp operating time and reset the lamp counter.

When the lamp life is left 0 hour, the Lamp replacement icon (Fig.1) will appear on the screen, indicating that the end of lamp life is reached.

When replacing the projection lamp, reset lamp counter. See "Resetting the Lamp Counter" on page 68.

Note:

The Lamp replacement icon (Fig.1) will not appear when the Display function is set to Off (p.49), during “Freeze” (p.28) or “No show” (p.29).

Fan Control Setting

140º

50º Lamp counter 50º

40º

90º

40º

 

180 º

 

Fig..1 Lamp replacement icon

This icon appears on the screen when the end of lamp life is reached.

Note:

At turning on, the icon (Fig.1) will appear.

61

Page 61
Image 61
Eiki LC-WB42N owner manual Fan Control Setting, Fan control, Lamp counter, Note