Lamp Replacement

Lamp Replacement

WARNING:

-For continued safety, replace with a lamp assembly of the same type.

-Allow the projector to cool for at least 45 minutes before you open the lamp cover. The inside of the projector can become very hot.

-Do not drop the lamp module or touch the glass bulb! The glass can shatter and cause injury.

Procedure

1 Turn off the projector and disconnect the AC cord. Allow the projector to cool for at least 45 minutes.

2 Loosen 2 screws with a screwdriver and open the lamp cover.

3 Loosen 2 screws and pull out the lamp assembly by grasping the handle. 4 Replace the lamp assembly securely and tighten 2 screws.

5 Close the lamp cover and tighten 2 screws.

6 Connect the AC cord to the projector and turn on.

7 Reset the Lamp Replace Counter, see below explanation.

Note:

-Do not reset the Lamp Replace Counter, except after lamp is replaced.

-The projector can not be turned-on with lamp cover removed, because when the lamp cover is removed, the interlock switch is also released to switch off the mains power for safety.

How to reset Lamp Replace Counter

1 Turn the projector on, and press the MENU button to display the On- Screen Menu. Press the POINT LEFT/RIGHT buttons to move a red frame pointer to SETTING menu icon.

2 Press the POINT DOWN button to move the red frame pointer to “Lamp counter” and then press the SELECT button. The next box appears.

3 Press the POINT UP/DOWN buttons to select Reset and then press the SELECT button. The "Lamp replacement counter reset?" appears. Move the pointer to [Yes] and the press the SELECT button.

4 Another confirmation dialog box appears and select [Yes] to reset Lamp Replace Counter .

Please refer to the owners manual for further information.

ORDER REPLACEMENT LAMP

Type No.

Service Parts No.

POA-LMP101 610 328 7362

Lamp cover

Handle

Lamp Assembly

Screws How to reset Lamp Replace Counter

Recommendation

Should the air filter become clogged with dust particles, it will reduce the cooling fan’s effectiveness and may result in internal heat build up and short lamp life. We recommend clean- ing the air filter after the projection lamp is replaced.

Refer to “Air Filter Cleaning”.

How to check lamp used time

The LAMP REPLACE indicator will light when the total lamp used time (corresponding value) reaches 2,500 hours. This is to indicate that lamp replacement is required. The total lamp used time is calculated by using the below expression;

Total lamp used time = Teco + Tnormal x (1.666) Teco: used time in Eco mode

Tnormal: used time in Normal and Auto mode You can check the lamp counter following procedure.

1 Press and hold the POWER ON-OFFbutton on the projector or the remote control unit for more than 20 seconds.

2 The projector used time and lamp used time will be displayed on the screen briefly.

You can also check "Lamp Counter" in "Setting Menu". This value is actual lamp used time.

"Lamp Time" = Teco + Tnormal

Lamp Counter Display

 

 

 

Projector used time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Counter

 

 

 

 

 

 

 

 

 

 

 

 

Projector

 

 

 

475H

 

 

 

 

 

 

 

 

Lamp

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

100H

 

 

 

 

 

 

 

 

 

 

Eco

375H

 

 

 

 

 

 

 

 

Corresponding value

542H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total lamp used time (corresponding value)

Setting Menu

 

 

 