Eiki LC-X71 LC-X71L Optical Adjustments, Contrast adjustment, R/G/B-Contrast Adjustment, 2

Models: LC-X71 LC-X71L

1 107
Download 107 pages 61.58 Kb
Page 21
Image 21
Optical Adjustments

Optical Adjustments

Before taking optical adjustments below, remove the Cabinet Top and Main Board following to the “Mechanical Disassemblies”

Adjustments require a 2.0mm hex wrench and a slot screwdriver.

Note: Do not disconnect connectors K8L, K8X, K8D, K8G and K8E on the main board, because the projector can not turn on due to operate the power failure protection.

WARNING : USE UV RADIATION EYE AND SKIN PROTECTION DURING SERVICING

CAUTION: To prevent suffer of UV radia- tion, those adjustments must be completed within 25 minutes.

Contrast adjustment

[Before Adjustment]

- Input a 100% of black raster signal.

[R/G/B-CONTRAST ADJUSTMENT]

A

 

1 Loosen a screw A (Fig.1-1/1-2) on the polarized glass mounting

 

base which you intend to adjust.

 

2 Turn the polarized glass mounting ass'y and the polarized glass

 

mounting base at the same time as shown in Fig.1-1to obtain the

 

darkest brightness on the screen.

 

Note: Both of them should be moved at the same time and in the

 

same direction.

 

3 Tighten the screw A to fix the polarized glass mounting base.

 

Polarized glass mounting ass'y

Polarized glass Contrast adjustment mounting base

Fig.1-1

Repeat steps 1 to 3 for remaining polarized glasses.

Main Board

R-Polarized Glass

 

Mounting Ass'y

 

and Base

 

A

G-Polarized Glass

Mounting Ass'y

and Base

A

B-Polarized Glass A

Mounting Ass'y

and Base

Fig.1-2

- 21 -

Page 21
Image 21