Eiki LC-X71 LC-X71L c Fan Voltage adjustment, b PSIG adjustment, v Video Center adjustment

Models: LC-X71 LC-X71L

1 107
Download 107 pages 61.58 Kb
Page 26
Image 26
cFan Voltage adjustment

Electrical Adjustments

cFan Voltage adjustment

1.Enter the service mode.

2.Connect a digital multimeter to test point “A” (+) and chassis ground (-). (as shown below)

3.Select group no. “140”, item no. “B” and change data value to adjust the fan max. output voltage to be 13.5 ±0.05V.

4.Select group no. “140”, item no. “C” and change data value to adjust the fan min. output voltage to be 5.0 ±0.05V.

5.Each fan should be adjusted refer to item 2 - 4.

Note:

The location of each fan is refer to "FAN control stage" of Chassis Description.

Test point "A"

Item No."B"

 

 

Item No."C"

Fan No.

TPFN3

0

 

1

FN903

TPFN7

2

 

3

FN907

TPFN6

4

 

5

FN906

TPFN4

6

 

7

FN904

FAN1

8

 

9

FN901

 

 

 

 

 

FN902

FAN2

10

 

11

FN905

 

 

 

 

 

 

bPSIG adjustment

1.Receive the 16-step gray scale computer signal with Input 1 [RGB(Analog)] mode.

2.Enter the service mode.

3.Connect an oscilloscope to test point “TP533” (+) and chassis ground (-).

4.Select group no. “200”, item no. “3” and change data value to adjust amplitude “a” to be 10.8 ±0.1V.

5.Select item no. “6” and change data value to adjust amplitude “b” to be 3.8 ±0.1V.

6.Connect an oscilloscope to test point “TP563” (+).

7.Select group no. “200”, item no. “4” and change data value to adjust amplitude “a” to be 10.8 ±0.1V.

8.Select item no. “7” and change data value to adjust amplitude “b” to be 3.8 ±0.1V.

9.Connect an oscilloscope to test point “TP503” (+) .

10.Select group no. “200”, item no. “5” and change data value to adjust amplitude “a” to be 10.8 ±0.1V.

11.Select item no. “8” and change data value to adjust amplitude “b” to be 3.8 ±0.1V.

(b) (a)

vVideo Center adjustment

1.Receive the 16-step gray scale computer signal with Input 1 [RGB(Analog)] mode.

2.Enter the service mode.

3.Connect a digital voltmeter to test point “TP531” (+) and chassis ground (-).

4.Select group no. “200”, item no. “0” and change data value to adjust the voltage to be 7.5 ±0.05Vdc.

5.Connect a digital voltmeter to test point “TP561” (+) and chassis ground (-).

6.Select item no. “1” and change data value to adjust the voltage to be 7.5 ±0.05Vdc.

7.Connect a digital voltmeter to test point “TP501” (+) and chassis ground (-).

8.Select item no. “2” and change data value to adjust the voltage to be 7.5 ±0.05Vdc.

nPC Black Level adjustment

1.Receive the 16-step gray scale computer signal with Input 1 [RGB(Analog)] mode.

2.Enter the service mode.

3.Connect an oscilloscope to test point “TP531” (+) and chassis ground (-).

4.Select group no. “200”, item no. “9” and change data value to adjust amplitude “a” to be 10.6 ±0.1V.

5.Connect an oscilloscope to test point “TP561” (+) and chassis ground (-).

4.Select group no. “200”, item no. “10” and change data value to adjust amplitude “a” to be 10.6 ±0.1V.

3.Connect an oscilloscope to test point “TP501” (+) and chassis ground (-).

4.Select group no. “200”, item no. “11” and change data value to adjust amplitude “a” to be 10.6 ±0.1V.

black level

(a)

black level

- 26 -

Page 26
Image 26
Eiki LC-X71 LC-X71L c Fan Voltage adjustment, b PSIG adjustment, v Video Center adjustment, n PC Black Level adjustment