1: Jan. 9 2004

[5] ADJUSTMENTS

1. Paper width detection level setting (adjustment)

 

 

LED 6

LED 5

 

LED 4

 

LED 3

LED 2

LED 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PUNCH key

Operator panel

1)Enter the diag mode.

Press and hold PUNCH key and START key, and turn on the power of the main unit.

The LCD display of the main unit turns on and off, then turns on again.

Check that LED1 is flashing, and release PUNCH key and START key.

2)Press START key.

The display changes to the diag mode.

3)Press PUNCH key and STAPLE key to set to the paper width detection level setting (adjustment) mode.

The diag mode is displayed by combination of LED lighting.

 

 

: Lighting

: OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diag mode

Diag mode

LED lighting

 

 

No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Paper width detection level

6 5 4 3 2 1

 

 

 

 

setting (adjustment) mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STAPLE key

START key

4)Press START key. (The selected diag mode is executed.)

5)Check that LED2 is flashing, and set the paper guide to the max. width position.

6)Press START key.

7)Check that LED3 is flashing, and set the paper guide to A4R width position.

8)Press START key.

9)Check that LED4 is flashing, and set the paper guide to A5R width position.

10)Press START key.

11)Check that LED5 is flashing, and set the paper guide to the min. width position.

12)Press START key.

When setting (adjustment) is completed normally, LED1 lights up. When it is failed, LED1 flashes more rapidly.

AR-CF2 ADJUSTMENTS 5 - 1

Page 11
Image 11
Sharp service manual Paper width detection level setting adjustment, Led, Off, AR-CF2 Adjustments 5