1: Jan. 9 2004

Problem

Tray alarm is displayed on the system display.

 

Case1

Cause

Sub-tray pulling detection sensor fault

 

 

Check and

Measure a voltage on TP14 on the

 

 

remedy

controller PCB and check that 5 V is

 

 

 

observed when the sub-tray is in place,

 

 

 

and that 1 V or less is observed when the

 

 

 

sub-tray is pulled out. Replace the sensor

 

 

 

if the measured voltage exceeds these

 

 

 

ranges.

 

Case2

Cause

Sub-tray pulling detection sensor fault

 

 

Check and

Measure a voltage of TP15 on the

 

 

remedy

controller PCB and check that 5 V is

 

 

 

observed when the tray is in place, and

 

 

 

that 1 V or less is observed when the tray

 

 

 

is pulled. Replace the sensor if the

 

 

 

measured voltage exceeds these ranges.

 

Case3

Cause

Controller PCB fault

 

 

Check and

If the problem is not solved by a change in

 

 

remedy

the sensor level after the above cases 1

 

 

 

and 2 are confirmed, replace the

 

 

 

controller PCB.

 

Problem

Cover open is displayed on the system display.

 

 

 

Case1

Cause

JAM cover open/close switch fault

 

 

 

 

Check and

Check continuity between the switch

 

 

 

 

remedy

contacts., Replace the switch if no

 

 

 

 

 

conduction is measured.

 

 

 

Case2

Cause

Reverse unit open/close sensor fault

 

 

 

 

Check and

Measure a voltage of TP9 on the

 

 

 

 

remedy

controller PCB and check that 1 V or less

 

 

 

 

 

is observed when the reverse unit is

 

 

 

 

 

open, and that 5 V is observed when the

 

 

 

 

 

reverse unit is closed. Replace the sensor

 

 

 

 

 

if the measured voltage exceeds these

 

 

 

 

 

ranges.

 

 

 

Case3

Cause

Rack cover open/close sensor fault

 

1

 

 

Check and

Measure the voltage of TP10 on the

 

 

 

 

remedy

control PWB and check that it is 1V or

 

 

 

 

 

less when the base cover is opened and

 

 

 

 

 

5V when closed.

 

 

 

 

 

If the voltage is outside the above

 

 

 

 

 

specifications, replace the sensor with a

 

 

 

 

 

new one.

 

 

 

Case4

Cause

Controller PCB fault

 

 

 

 

Check and

If the problem is not solved by a change

 

 

 

 

remedy

in the sensor level after the above cases

 

 

 

 

 

1 to 3 are confirmed, replace the

 

 

 

 

 

controller PCB.

 

 

 

 

 

 

 

 

Problem

Inserter unset is displayed on the system display.

 

 

 

Case1

Cause

Set sensor fault

 

 

 

 

Check and

Measure a voltage of TP16 on the

 

 

 

 

remedy

controller PCB and check that 5 V is

 

 

 

 

 

observed when the inserter is set, and

 

 

 

 

 

that 1 V or less is observed when the

 

 

 

 

 

inserter is not set. Replace the sensor if

 

 

 

 

 

the measured voltage exceeds these

 

 

 

 

 

ranges.

 

 

 

Case2

Cause

Controller PCB fault

 

 

 

 

Check and

If the problem is not solved by a change

 

 

 

 

remedy

in the sensor level after the above case 1

 

 

 

 

 

is confirmed, replace the controller PCB.

 

Problem

The registration clutch does not perform.

 

Case1

Cause

Loose contact of the clutch connector

 

 

 

terminal

 

 

Check and

Check continuity of the connector

 

 

remedy

contacts. (CN4)

 

Case2

Cause

Disconnection of the clutch coils

 

 

Check and

Inspect the coils for continuity. Replace

 

 

remedy

the coils if no continuity is measured.

 

Case3

Cause

Controller PCB fault

 

 

Check and

If the clutch does not perform in the clutch

 

 

remedy

single operation mode, replace the

 

 

 

controller PCB.

AR-CF2 TROUBLESHOOTING 8 - 2