Eiki LC-X71 LC-X71L service manual Error history log, The Latest Error

Models: LC-X71 LC-X71L

1 107
Download 107 pages 61.58 Kb
Page 51
Image 51
Error history log

Chassis Description

Error history log

The projector provides the error history log function. To check the logs, you need to enter the service mode and select Group No. "91" and Item No. "0" to "49". The error code is displayed on the Data column. The description of the error code is listed on the table below.

How to enter the service mode and selection of the group and item, see "Service Adjustment Menu Operation" on page 24.

 

Group No.

Item No.

Data (Error Code)

<-- See table below

 

 

 

 

 

 

 

 

91

0

<-- The Latest Error

 

 

 

1

 

 

 

 

 

2

 

 

 

 

 

3

 

 

 

 

 

:

:

 

 

 

 

 

:

:

 

 

 

 

 

:

:

 

 

 

 

 

48

 

 

 

 

 

49

 

 

 

 

 

 

 

 

 

 

Error

Error Code

Error Information

Normal

0

-

 

 

1000

PJNET,

S5V

 

1001

AV,

-5V

 

1002

AV,

S5V

 

1003

MAIN,

S-5V

 

1004

M/A,

12V

 

1005

FAN,

16V

 

1006

SWFPGA,

1.2V

 

1007

SWFPGA,

2.5V

 

1008

ANALOG,

1.8V

Power Failure

1009

FPGA,

1.5V

 

1010

GAMMA,

15.5V

 

1011

MAIN,

6V

 

1012

MAIN,

3.3V

 

1013

ANALOG,

3.3V

 

1014

ANALOG,

5V

 

1015

GAMMA,

1.8V

 

1016

LAMP FAN,

16V

 

1017

Factory use

 

 

1018

Factory use

 

 

1019

Factory use

 

 

2000

Sensor A detects abnormal temperature.

 

2001

Sensor A fails measurement.

 

2100

Sensor B detects abnormal temperature.

 

2101

Sensor B fails measurement.

Temperature Error

2102

Sensor B-A temperature error

 

2200

Sensor C detects abnormal temperature.

 

2201

Sensor C fails measurement.

 

2202

Sensor C-A temperature error

 

3000

Lamp fails on.

Lamp Error

3001

lamp goes out.

 

3002

Communication error on lamp

 

 

 

 

 

 

- 51 -

 