Eiki LC-X71 LC-X71L service manual Control Port Functions

Models: LC-X71 LC-X71L

1 107
Download 107 pages 61.58 Kb
Page 54
Image 54
Manual background

Control Port Functions

Pin No.

Function Name

Function

Polarity

I/O

137

GND

Power (0V)

-

-

138

PW_RESET

Reset for PW

Reset with L>H>L

O

139

1.9V

Power (1.9V)

-

-

140

PW_SEL

PIXEL 232C Selection

SH:H, PW:L

O

141

EXP_RESET

I/O Expander Reset Signal

Reset: H

O

142

RESET_GAM

Reset for Digital Gamma IC

 

O

143

TDO [for ICE]

Test Data output

-

O

144

(Not used)

 

(Open)

O

145

(Not used)

 

(Open)

O

146

SH_FPG_WAIT

Hardware Wait Request

Wait with L

I

147

RESETM

Manual Reset Request

-

I

148

(Reserved)

Analog Trigger/Inout Port H

(Open)

I

149

(Not used)

 

(Pull-down)

I

150

ASEMD0 [for ICE]

ASE Mode

-

I

151

ASEBRKAK [for ICE]

ASE Brake

-

O

152

(Not used)

 

(Pull-up)

I

153

AUDATA[3] [for ICE]

AUD data

-

O

154

AUDATA[2] [for ICE]

AUD data

-

O

155

GND

Power (0V)

-

-

156

AUDATA[1] [for ICE]

AUD data

-

O

157

1.9V

Power (1.9V)

-

-

158

AUDATA[0] [for ICE]

AUD data

-

O

159

GND

Power for Inout/Output(0V)

-

-

160

TRST [for ICE]

Test Reset

-

I

161

3.3V

Power for Inout/Output(3.3V)

-

-

162

TMS [for ICE]

Test Mode Switch

-

I

163

TDI [for ICE]

Test Data Input

-

I

164

TCK [for ICE]

test Clock

-

I

165

(Not used)

 

(Pull-down)

I

166

(Not used)

 

(Pull-down)

I

167

LAMP_DET

Lamp Fail Detection I Lamp Failure Detection until Dimmer Starts

L: Lamp fail

I

168

SWF_INIT

Config. status signal

 

I

169

MD0

Clock Mode Setting [Default:L]

L fixed

I

170

1.9V

PLL1 Power (1.9V)

-

-

171

CAP1

PLL1 External Condenser - [470pF]

-

-

172

GND

PLL1 Power (0V)

-

-

173

GND

PLL2 Power (0V)

-

-

174

CAP2

PLL2 External Condenser - [470pF]

-

-

175

1.9V

PLL2 Power (1.9V)

-

-

176

AUDCK [for ICE]

AUD Clock

-

I

177

GND

Power (0V)

-

-

178

1.9V

Power (1.9V)

-

-

179

(Reserved)

Clock Oscillator

(Open)

-

180

EXTAL

External Click/X'TAL

-

I

181

SWF_DONE

Config. process finishing signal

 

I

182

BOX_SW

Detect on/Off for PJ-Net Board

L: Yes, H: No

I

183

FPGA_nSTATUS

Error Detection during the Config.

H:Error

I

184

FPGA_CONF_DONE

OK Detection during the Config.

H:OK

I

185

SH_FLASH_WP

Flash IC Write Protect

L: Protect

O

186

PFC_SW_EX

PFC_SW

 

O

187

SWF_D0

Config. data

 

O

188

GND

Power for Inout/Output(0V)

-

-

189

CKIO

System Clock IO

-

I/O

190

3.3V

Power for Inout/Output(3.3V)

-

-

191

SH_LB_UART

Dimmer Control

H: at lamp ON

O

192

(Not used)

 

(Open)

-

193

(Not used)

 

(Open)

-

194

(Not used)

 

(Pull-up)

-

195

SH_EX_UART

Send Data2 [External]

19200 or 9600bps

O

196

(Not used)

 

(Pull-up)

-

197

(Not used)

 

(Pull-up)

-

198

LB_SH_UART

Dimmer control and lamp error detect

-

I

199

(Not used)

 

(Pull-up)

-

200

GND

Power (0V)

-

-

201

EX_SH_UART

Receive Data2 [External]

19200 or 9600bps

I

202

1.9V

Power (1.9V)

-

-

203

(Not used)

 

(Pull-up)

I

204

FPGA_NCONFIG

Start config.

L -> H start

O

205

NET_H/L

Request command for PJNet

Active L

O

- 54 -

Page 54
Image 54
Eiki LC-X71 LC-X71L service manual Control Port Functions