Power failure detection system

Chassis Description

Power failure detection system

Detection of Power failure

The projector provides a protection circuit to prevent the secondary failure when the power failure, fans failure or tem- perature failure occurs on the projector. The power failure detection lines "MAIN_6V_PF", "MAIN_-5V_PF", etc. are connected to the main power supplies. When the failure occurs, IC801<CPU> receives an error information through the power failure detection lines and turns off the signal "IC_RESET_CPU" output from pin 211 to stop the power supply.

The power failure detection signals are sent to IC4801<I/O expander> and then sent to IC801<CPU>.

Error information table

IC

Pin

Signal Name

Connection

Error Information

 

64

PJ_5V_PF

PJNET S5V

PJNET,

S5V

 

65

-5V_AV_PF

AV S-5V (AV BOARD)

AV,

-5V

 

66

S5V_AV_PF

AV S5V (AV BOARD)

AV,

S5V

 

67

MAIN_-5V_PF

SUB_POWER S-5V (MAIN)

MAIN,

S-5V

 

68

M/A_PF

MOTOR&AUDIO 12V

M/A,

12V

 

69

FAN_PF

FAN 16V

 

FAN,

16V

 

70

SWF_1.2V_PF

SW FPGA 1.2V

SWFPGA,

1.2V

IC4801

71

SWF_2.5V_PF

SW FPGA

2.5V

SWFPGA,

2.5V

TIC81592GPBM

72

VDEC_1.8_PF

CXD3807

1.8V

ANALOG,

1.8V

 

73

FPGA_1.5V_PF

FPGA 1.5V

FPGA,

1.5V

 

74

GAM_15.5V_PF

GAMMA 15.5V

GAMMA,

15.5V

 

77

MAIN_6V_PF

SUB POWER 6V (MAIN)

MAIN,

6V

 

78

MAIN_3.3V_PF

SUB_POWER 3.3V (MAIN)

MAIN,

3.3V

 

80

AD_3.3V_PF

AD9882 3.3V

ANALOG,

3.3V

 

82

AD_5V_PF

AD9882 5V

ANALOG,

5V

 

83

GAM_1.8V_PF

GAMMA 1.8V

GAMMA,

1.8V

 

56

LAMP_FAN_PF

LAMP_IN_FAN 16V

LAMP FAN, 16V

 

 

 

 

 

 

 