39
Chapter4SelfCalibration
Setting Adjustment Target
Set the calibration targets for SelfCalibration.
Procedure
1. Choose “SelfCal ibration” from the Adjustment menu, and press .
2. Choose “Sett ings” from “SelfCalibration”, and press .
3. Choose “Target” from “Set tings”, and press .
4. Use or to select the mode to change, and press .
The target setting menu appea rs.
5. Use or to select the items to change, and press .
Settings Adjustable Range Setting
Brightness 30cd/m2to200cd/m2Setthebr ightnessofthemonitorusing
thebrightnessvalue(cd/m2).
WhitePoint White(x)/White(y) 0.240 0-0.4500*1 SetthemonitorWhitePointusingthe
colorcoordinateorTemperature.
Temperature 4000K-10000K
(100KUnit)*2
ColorGamut ColorGamut Native Donotadjustthecolorgamut.
User Adjustthecolorgamut.
ForeachofRed/Green/
Blue
0.0000-1.0000 Tocalibratethemonitorcolor
reproductiongamut,setthecolor
coordinatesforred,green,andblue.
Clipping On/Off Thisfu nctionallowsyoutodisplaythe
monitorwiththecolorsbasedonthe
speciedcolorgamut.
(“Tosetclipping”(page22))
Gamma 1.6-2.7
(0.1Unit)*3
Setthemonitorgammavalues.
*1 Whenthecolorcoordinatesareset,thetemperaturec hangesto“User”.
*2 Whenthetemperatureisset,thexandycoordinatesofthewh itepointaresetautomatically.
*3 Thesebecome“Fixed”whencalibratingwit hColorNavigator.
6. Use or for adjustment.
7. Press to exit.
The calibration targets are set.
Attention
• Only set the c olor gamut calibration when the target color ra nge is precisely known.
• If ColorNavigator was use d to calibrate the grey balance, do n ot change the gamma setting value s.

4-2. Executing SelfCalibration

Procedure
1. Choose “SelfCal ibration” from the Adjustment menu, and press .
2. Choose “Execute” from “ SelfCalibration”, and press .
The built-in calibration sensor is activat ed, and SelfCalibration is execut ed.
Attention
• To execute SelfCalibrat ion, it is necessary to set the calib ration details. For more information , see “4-1. Setting
Calibration Details” (page 36).
• After s electing “Execute”, aging may be executed before the bui lt-in calibration sensor is executed.