Design Spot 575B™
©Elation Professional, Los Angeles CA. 27 Design Spot 575B™
don’t.
9.3.4. Lamp off via external DMX controller
With this function you can select if you can switch the lamp off via an external controller.
Select “ON” by turning the LCD controls if you wish to enable this function or “OFF” if
you don’t.
9.3.5. Lamp Off if no DMX
With this function you can select to switch off the lamp off automatically if there is no DMX
signal). Select “ON” by turning the LCD controls if you wish to enable this function or
“OFF” if you don’t.
9.3.6. Lamp on at temp.
With this function you can set the inside temperature from which the projector will strike
the lamp after an automatic lamp shut off.
9.3.7. Lamp off at temp.
With this function you can set the inside temperature at which the projector will
automatically switch the lamp off. Turn the LCD controls to select the maximum inside
temperature between 80° C and 139° C. Inside temperatures below 90° C are not critical.
90° C and more should lead to the lamp being switched off. Please note that the outside
temperature should not exceed 45° C.
9.4 Personality:
9.4.1. Status setting
A. Address via DMX - This function allows the DMX address to remotely be adjusted
from a DMX console. This setting requires special settings for both the controller and
the fixture. RDMX is on by default. For operational instructions please see Section
10/Page 32 of this manual “Remote DMX addressing.”
B. Run if no DMX – This function dictates how the fixture will function if it looses
DMX signal during normal operation. The default function is set to hold, in which