Design Spot 575B™

OK ￿

NO ￿

5.Once the lamp has been inserted into the socket, gently slide the socket assembly back into place and secure with the four retaining screws.

6.Reset the lamp run time in the system menu.

7.Always be sure to optimize the lamp after lamp replacement.

Do not operate this device with open cover

Lamp Optimization

The lamp orientation and optimization must be adjusted after every lamp change. This procedure centers the lamp in the reflector. Proper optimization will increase lamp life and ensure a bright, crisp, and even output. Improper optimization may add a yellow tint to the lamp output and reduce intensity. The minimum deviation amount is 1.0mm. Running the fixture within a lower deviation can cause damage to the lamp and/or lens.

The Design Spot 575B™ lamp holder is aligned at the factory. However, due to slight imperfections in all lamps, fine adjustments will improve light performance. Please follow the procedure below for proper lamp optimization:

1.Using either a DMX controller or the control panel on the unit, strike the lamp and focus the light on a flat surface (beam open, white, no gobo, no effect).

2.Center the hot-spot (the brightest part of the beam) using the 3 adjustment screws labeled 1, 2, and 3 as illustrated on the next page. Turn one screw at a time to drag the hot-spot diagonally across the projected image. If you cannot detect a hot-spot, adjust the lamp until the light is even.

3.To reduce a hot-spot, pull the lamp in by turning all three screws clockwise a 1/4-turn

©Elation Professional, Los Angeles CA.

12

Design Spot 575B™

Page 12
Image 12
Elation Professional 575B manual Lamp Optimization