COM Environment Setup (/Y)

Function

This function sets up the environment of COM port.

Starting method

int

argc = Number of parameter arguments

char*

argv[] = { "fl", "/Y={communication speed, COM specification,,,,,,,}" }

DoFlink(argc, argv)

If the parameters for the Y option do not have to be entered, enter only comma separators. If this is the case, default values will be automatically used.

Communication speed

Sets up the communication speed (baud rate) when communication is executed through COM1 (RS-232C port) or Satellite I/O Box. The setting baud rate cannot be valid for other communications , between HT and HT or through Master I/O Box.

Input parameter

Baud rate (bps)

Remark

1200

1200

 

2400

2400

 

4800

4800

 

9600

9600

Default

19 K

19200

 

38 K

38400

 

57 K

57600

 

115 K

115200

 

COM specification

Specifies COM port for the communication.

Input parameter

COM port

Remark

1

COM1 (RS-232C)

 

2

COM2 (IrDA)

Default

Starting method

argc = 2

argv[] = { “fl” , “/Y={,1,,,,,,,}” }

253