Acquisition of Low Battery Voltage Status

An APM (Advanced Power Management) BIOS has been installed in this terminal. This function is

used to directly refer the hardware conditions which are translated into input signals for the APM

BIOS.

SYNTAX

int SYS_GetLBStatus();

INPUT

 

None

 

OUTPUT

 

b0

Reserved

b1

LB1 event: Main battery voltage low.

b2

LB2 event: Sub-battery voltage low.

b3

LB3 event: Memory card battery voltage low.

b4 to b7

Reserved