68 I/O modules
22F
Con 111
1 2 Con 110 123456
Con 108
1 2
Con 109
123456
RE106
RE105
RE104
RE103
RE102
Con 107 123
RE101
Address
Inp
Con 115
Function I/O:s
PTD5
Type of I/O card
+5V
Start permitted
Central booking / payment
EBS / PCB / Camping
230V
0V
+24V
24V
Start permitted
Central booking / payment
EBS / PCB / Camping
Neutral
Line
Com. 24V(-)
Com. 100 -240V
Blocking of start
Heating pause
Liq. det. empty
Temporary pause
Common outputs
Power for outputs
Common
Liquid det. sign 1
Liquid det. sign 2
Liquid det. sign 3
Liquid det. sign 4
Liquid det. sign 5
Program run NC
Program run NO
2
2
F
Com. 24V(-)
Start permitted Central payment
Plexa Compact
Status machine
M1 M1 S1 S1
Com.
Com.
Input 1
Input 2
Input 3
Input 4
Output 1
Output 2
Output 3
Output 4
Output 5
Output 6 NC
Output 6 NO
6944
• Thecentralpaymentorbookingsystemshalltransmitanactive(high)signalto
the washing machine once permission has been granted to start the machine.
Thesignalmustremainactive(high)untilthemachinestarts.Afeedbacksignal
willbepresentonconnection18andremainactive(high)whilstthewash
programisrunning.Thefeedbacksignalispoweredby230Vfromconnection
19orexternal24V.