Elmira Stove Works 1954 manual Location, Temperatures, Minimum Clearances to Combustibles

Models: 1954

1 32
Download 32 pages 38.66 Kb
Page 6
Image 6
Location

Location

If possible, the range should be located to avoid the main “traffic path” through the kitchen or where an open door might block a passageway or create an awkward working situation. If possible, it should be so located where cabinet working space is available on either side. Drafty locations should be avoided to prevent gas burner outage and poor air circulation.

Temperatures

To cook, you must have heat. Some parts of the range are therefore going to get warm or even hot. Consider this in choosing a range location. Do not leave children alone or unattended near the range when it is in use. Let burner grids and other surfaces cool before touching them or leaving them where children can reach them.

Clearances

This range may be installed with adjacent surfaces touching the base cabinets and the back flush with the back wall. Models 1955 and 1956 gas ranges require a CGA/AGA approved stainless steel gas flex line or a flexible copper coil 1/2" in diameter and at least three feet long so the range can be moved for service.

To eliminate the risk of burns or fire by reaching over heated surface burners, cabinet storage above the range should be avoided. If overhead storage is unavoidable, clearances between the cooking surface and unprotected wood or metal overhead cabinets must be no less than 32". The clearances on electric models between the cooktop and unprotected overhead cupboards is 30". This distance may be reduced to 24" when the bottom wood or metal cabinets are protected by not less than 1/4" thick flame retarding millboard covered with not less than No. 28MSG sheet steel, 0.015" thick stainless steel, 0.024" thick aluminum or 0.020" thick copper.

NOTE: Clearances specified to combustible construction (walls and materials) are based on a temperature rise of wood resulting from appliance operation. These clearances are suitable for walls of studding, lath and plaster or other types of combustible material which have a density of 20 lbs. per cu. ft. or more. No evaluation of clearances has been made for low density cellulose, fibre board and similar materials which have a density of less than 20 lbs. per cu. ft., nor to plastic tiles or sheeting.

The maximum depth of upper cabinets installed above the range is 13".

See the Minimum Clearances Chart for electric and gas models below.

Minimum Clearances to Combustibles

 

A

B

C

D

E

F

All Model Electric 1954

0"

0"

30"

0"

0"

13"

 

 

 

 

 

 

 

Combo Model 1954

3"Ht.Min.18”

3" Ht.Min.18”

32"

0"

0"

13"

All Gas Model 1956

3"Ht.Min.18”

3" Ht.Min.18”

32"

0"

0"

13"

1 = End of section of overhead cabinet

2 = Overhead center cabinet

3 = End wall or divider

Exhaust Hood Dimensions – 30" W x 22" D x 6" H Hood should be installed 28" to 30" from the bottom of hood to the range cook top. See Full Installation information in Exhaust Hood Manual.

It is the responsibility of the installer to comply with the installation clearances specified in this manual.

Cabinet Openings

This range will fit into a 30 1/8" cabinet opening.

Leveling Your Range

Place rack in oven. Place level on rack, first side to side, then front to back.

If the range is not level, adjust leveling legs up or down with pliers or your fingers until range is level.

NOTE: Oven must be level for satisfactory baking performance.