Elmo HV-7000SX Data format specifications, Svga XGA Sxga, Command Parameter Data Visual Presenter

Models: HV-7000SX

1 40
Download 40 pages 52.5 Kb
Page 34
Image 34

Function

Command

Parameter

Data

Comments

 

 

 

 

 

 

 

 

 

Resolution

RS

0 (VGA)

 

 

 

 

 

Command to switch the resolution.

 

 

 

 

 

 

 

 

 

 

selection

 

1

(SVGA)

 

 

 

 

 

 

 

 

2

(XGA)

 

 

 

 

 

 

 

 

3

(SXGA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gamma

GM

0 (1.0)

 

 

 

 

 

Command to switch the gamma setting value of the image.

 

 

 

 

 

selection

 

1

(0.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image rotation

RO

0 (OFF)

 

 

 

 

 

Command to rotate the image.

 

 

 

 

 

 

 

1

(90°)

 

 

 

 

 

 

 

 

2

(180°)

 

 

 

 

 

 

 

 

3

(270°)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Aparture

AP

0 (OFF)

 

 

 

 

 

Command to switch the sharpness (edge effect) of the image.

 

 

 

 

 

selection

 

1

(ON)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

DF

0

 

 

 

 

 

 

Command to reset to the initialized mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status request

QS

0

 

 

 

 

 

 

Command to inquire the status of the equipment.

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ROM version

QR

0

 

 

 

 

 

 

Command to refer to the ROM version.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acknowledge

SA

0 (OFF)

 

 

 

 

 

Command to select the command acknowledgement for each

 

 

 

 

 

check

 

1

(ON)

 

 

 

 

 

operation command.

 

 

 

 

 

 

 

 

 

Add CR

SC

0 (OFF)

 

 

 

 

 

Command to add CR [0Dh] to the end of the acknowledge data

 

 

 

 

 

command

 

1

(ON)

 

 

 

 

 

Default is OFF.

 

 

 

 

 

 

 

 

 

 

Note: " " in the data column means that SPACE [20H] should be transmitted twice.

Data format specifications

This command is executed in the form of 1-command/1 packet. The next command is not accepted until the previous processing is completed.

·The communication command always starts with STX (Start of Text), and ends with ETX (End of Text).

·If the communication format or command name is wrong, NAK (Negative Acknowledgement) will be sent from the Presenter as a result of failing to receive correctly.

·When the communication format is correctly received, the Presenter sends ACK (Normal Acknowledgement).

Transmission Command (PC Visual Presenter)

Each operation command is executed in ASCII code, and transmitted in a set of 7 bytes as follows:

(PC)

S T X

Command

Parameter

Data

E T X

(Visual Presenter)

ACK

33

Page 34
Image 34
Elmo HV-7000SX instruction manual Data format specifications, Svga XGA Sxga, Transmission Command PC Visual Presenter