MagTek Device Drivers for Windows

Property

Access

Description

offline_enc

R/W

Set to 1 to enable encode capability in standalone mode with

 

 

keyboard; 0 prevents standalone encoding (MT-95).

oper_tout

R/W

Operational timeout in seconds (15-255). (IntelliPIN)

pin_blk_fmt

R/W

PIN block format (IntelliPIN):

 

 

ansi (ANSI 9.8) or ibm (IBM 3624)

pinfilldig

R/W

PIN fill digit (0..9, A..F) when pin_blk_fmt is ibm (IntelliPIN)

port_name

R

Indicates the virtual port number (e.g., COM6) derived from the

 

 

friendly port name.

pwroffdelay

R/W

Power off time delay in minutes (5-255). (IntelliPIN)

s_down_tout

R/W

Shutdown timeout in hours (1-31). Set to 0 to disable. (IntelliPIN)

track1ss

R

Indicates Start Sentinel on Track 1 as received from the device.

track2ss

R

Indicates Start Sentinel on Track 2 as received from the device.

track2ss

R

Indicates Start Sentinel on Track 3 as received from the device.

trivpinchk

R/W

Set to 1 for trivial PIN checki.e., don’t allow 1234. (IntelliPIN)

trk_enable

R/W

Enable reading and writing of individual tracks. The value of this

 

 

property is a string of three characters, with 0 representing

 

 

disabled tracks and 1 representing enabled tracks, e.g., 110 enables

 

 

tracks 1 and 2 and disables track 3.

trk1data

R

Data from track 1 excluding start sentinel and end sentinel.

trk2data

R

Data from track 2 excluding start sentinel and end sentinel.

trk3data

R

Data from track 3 excluding start sentinel and end sentinel.

visa_mac1

R

Message authentication codes returned by device after PIN is

visa_mac2

 

collected (DUKPT mode only). (IntelliPIN)

visa_mac3

 

 

wr_coer

R/W

Encode Coercivity Mode (MT-95). Specifies the energy level used

 

 

to encode the magnetic stripe:

 

 

0 = automatic selection

 

 

1 = LoCo only mode

 

 

2 = HiCo only mode

wr_secure

R/W

0 indicates the card can be removed between a read and write

 

 

operation. Set this to 1 to turn on secure online encode mode (MT-

 

 

95).

xact_type

R/W

Transaction type – d = debit, c = credit (IntelliPIN).