Elo TouchSystems 1525L manual Power Builder Example

Models: 1525L

1 181
Download 181 pages 9.32 Kb
Page 139
Image 139
POWER BUILDER EXAMPLE

MagTek Device Drivers for Windows

POWER BUILDER EXAMPLE

The following example illustrates how to set up PowerBuilder (from Sybase) to read magnetic data from the IntelliPIN device. Since PowerBuilder does not interface to a serial port very easily, a third-party OCX is required. The first part of this application note shows how to load an ActiveX component. The main program script shows how to interface with the OCX, the MTD Windows Driver, and the MagTek device (in this case the IntelliPIN).

The following communication ActiveX components are available for use with PowerBuilder:

Product

Company

Web Site

Phone

IO ActiveX Control

Software Island

members.aol.com/easyio

N/A

Comm Library

EllTech

elltech.com

800-227-8047

COMM-DRV/LIB

WCSC

www.wcscnet.com

800-966-4832

In our example, we have chosen “IO ActiveX Control” from Software Island. Here is a method that can be used to install this component:

1.In a PowerBuilder application, open a new window.

2.From the “Controls” dropdown menu, select “OLE”.

3.From the “Create New” tab, select the intended OCX, for example, “IO Control”. (It is assumed that the OCX has already been registered by installing it according to the manufacturer’s directions.) Then click “OK”.

4.Left click anywhere on the open window and drop the component onto it.

5.Right click on the newly installed component and select “Properties”. Enter “mtd” into the “Name” text field. Enter “MTD OCX” into the “Display Name” and “Tag” text fields. Click “OK”.

6.Right click anywhere on the window outside the new component then select “Properties”. Enter “ole_io” into the “Title:” text field. Deselect the “Visible” check-off box so the window will not be shown then click “OK”.

7.Right click anywhere on the window outside the new component then select the “Script” option. Insert the following script into the “ole_io” window.

//////////////////////////////////////////////////////////

//

Window Script to

load OCX for Mag-Tek Driver.

//

//

This is the script for the invisible window that

//

//

contains the OLE

object.

//

//////////////////////////////////////////////////////////

integer result

result = mtd.object.Open("COM5:", "")

//COM5 is the virtual port name which was automatically

//assigned to IntelliPIN RS-232 Driver upon installation.

//It may be different for your installation.

if result < 1 then MessageBox("Open Read",result) return 0

END if

136

Page 139
Image 139
Elo TouchSystems 1525L manual Power Builder Example