Elo TouchSystems 1525L manual event, none

Models: 1525L

1 181
Download 181 pages 9.32 Kb
Page 107
Image 107
event

MagTek Device Drivers for Windows

event

Function

Response to an unsolicited event notification.

Syntax

none

 

Errors

none

 

Remarks

This response can occur when an unsolicited event, such as card inserted, occurs.

 

The format of the response is: /event n data

 

n is a numeric event code:

 

1

– medium has been inserted into the reader

 

2

– medium has been removed from the reader

data specifies the type of medium that was inserted/removed: M – magnetic

Events are sent to the application only if the c_events property is 1 (driver supports events) and the events_on property is set to 1 by the application.

If a card has already been inserted when the driver is opened, there will not be any

notification when events_on

is enabled. Consequently, it is recommended

that

/get card_stat be issued immediately after opening the driver to see if a

card

is blocking

the sensor.

 

 

 

Example If you wish to be notified when a card has been inserted into the PPINSERT:

 

Command

/set events_on 1<LF>

 

 

Response

/event

1

M<LF>

 

When a card is inserted into the slot.

get

Function

Get a property.

Syntax

/get prop

 

prop is one of the valid properties shown in Section 2 or any of those from data

 

parsing.

Errors

Remarks

Example

/get abc<LF> Since abc does not exist.

The driver sends a response in the format: /get prop val.

If the requested property does not exist, the val field will be empty, i.e., <LF> follows the prop field. If the command was cancelled, both the prop and val fields will be empty. In some cases, this command will interrogate the device to determine the property setting. Some properties cannot be interrogated if a command (such as read) is pending. The value will be null in this case.

If you wish to find out which tracks are enabled, request the trk_enable property:

Command

/get

trk_enable<LF>

Response

/get

trk_enable 110<LF>

Indicating track 1 & 2 are enabled, track 3 is disabled.

104

Page 107
Image 107