Description of the menu options R93

 

If such an IP address already exists in the network, shut down the device using the

 

address for the duration of the configuration and assign a different, free LAN IP address

 

to the cable modem.

Access-list

The access to “internal functions” of the router may be controlled by an access list in

 

TCP/IP applications.

 

The configuration data of the device are protected by a password, however this is always

 

transferred in plain text, making it possible in principle to detect it and for any computer

 

to read the configuration or to delete it. In order to prevent this from happening, the

 

access list can be used to determine which computers or which networks can access the

 

configuration.

For reasons of consistency, the access control is based on all “internal functions” of the router. The term "internal functions" refers to the following:

KTelnet server: The configuration interface based on the Telnet protocol

KTFTP server: The configuration interface based on the TFT protocol

KSNMP: the configuration interface based on the SNMP

Each of the maximum of 16 entries in the access list has the following structure:

IP-address

IP netmask

IP address of the authorized user (or user

IP network mask of the user circle

circle)

 

Once an IP workstation with its IP address and the network mask 255.255.255.255 is entered into the list, the internal functions of the router can only be accessed from this computer. Any requests from devices with different IP addresses are ignored.

If a complete network has access enabled to a ELSA MicroLink Cable, this can be done as follows for a class C network:

IP-address

192.234.222.0

IP netmask

255.255.255.0

 

With this entry all IP addresses in the class C network 192.234.222.0 are authorized to

 

use internal functions of the router.

ARP table

This option allows you to display the ARP table (ARP cache), which is managed

 

automatically for the purpose of mapping IP addresses onto physical terminal addresses.

 

Individual entries can be removed from this table but no new entries can be entered

 

manually.

ELSA MicroLink Cable

Page 101
Image 101
ELSA Cable manual Description of the menu options R93