Description of the menu options R105

 

/Firmware

 

 

 

Display and keyboard settings

 

Timeout-firmesafe

 

 

 

Time in minutes required to test new firmware

 

 

 

 

 

 

 

 

 

 

 

Test-firmware

 

 

 

Tests the inactive firmware

 

 

 

 

 

 

 

Firmware-upload

 

 

 

Initiates a firmware upload

 

 

 

 

 

 

Version table

The version table displays the firmware version and serial number of the device.

Ifc

Ifc

Module

Version

Serial-number

MicroLink Cable

1.00 22.03.99

0317.000.005

 

 

 

Table firmsafe This table provides the following details for the two firmware versions stored in the device: the position in memory (1 or 2), status information (active or inactive), the version number, the date, the size and the index (sequential number).

Position

Status

Version

Date

Size

Index

1

Inactive

1.60

23061999

690

6

2

Active

1.60

30061999

692

7

3

<loader>

1.60

07061999

64

0

 

 

 

 

 

 

Enter the following command to activate an inactive firmware version:

set <position number> active

Mode-firmsafeOnly one of the two firmware versions stored in the device can be active at any one time. When new firmware is loaded, the inactive firmware is overwritten. You can decide which firmware will be activated after the upload:

K'immediate': The first option is to load the new firmware and activate it immediately. The following situations can result:

The new firmware is successfully loaded and then operates as desired. Everything is then in order.

However, if the new firmware does not operate correctly, it may not be possible to communicate with the device after the restart. If an error occurs during the upload, the device automatically reactivates the previous firmware version and reboots the device.

K'login': To prevent problems caused by defective firmware, the second option will load the firmware and start it immediately.

In contrast to the first option, the firmsafe will wait until it has successfully logged on (via telnet). The new firmware will only be permanently activated when the login occurs successfully within the time set under 'Timeout firmsafe'.