Emerson 1500, 1000 user manual Figure, 2200—rearview, 3000—rearview, Introduction

Models: 1000 1500 2200 3000

1 32
Download 32 pages 13.16 Kb
Page 9
Image 9
Figure 3

Introduction

Figure 3

2200—rear view

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15A Output Circuit Breaker

Receptacles #3 and #4

 

 

 

 

 

Power Cord; 5-20P

for Receptacles #3 & #4

 

 

 

 

 

NEMA 5-15R

 

 

 

 

 

 

 

 

 

 

 

 

DB-9 Port

(not shown for clarity)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Contact

 

Liebert

 

Receptacles #1 and #2;

 

 

 

 

 

 

 

Receptacles

Closure)

 

30A Input

NEMA 5-20R T-Slot

 

 

 

 

 

 

 

 

#5 and #6

 

 

 

 

 

IntelliSlot

 

 

 

 

 

 

 

 

 

 

 

 

 

NEMA 5-15R

 

 

 

 

 

Port

Circuit Breaker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT

2

1

 

OUTPUT

2200—rear viewFigure 4 3000—rear view DC 48V

EPO

USB Port

 

External Battery

 

 

Cabinet Connector

 

Voltage Configuration

Network Surge

20A Input Circuit Breaker

15A Output Circuit Breaker

DIP Switch

Protection

Receptacles #1 and #2

for Receptacles #5 & #6

Figure 4 3000—rear view

 

 

15A Output Circuit Breaker

 

Power Cord; L5-30P

 

for Receptacles #3 & #4

Receptacles #3 and #4

 

 

 

(not shown for clarity)

 

 

 

 

 

 

NEMA 5-15R

 

NEMA L5-30R

 

Receptacles #1 and #2;

Liebert

30A Input

Receptacles

Receptacle

NEMA 5-20R T-Slot

IntelliSlot

 

Circuit Breaker

 

#5 and #6

Port

 

 

 

NEMA 5-15R

DB-9 Port

 

 

 

 

 

 

 

(Contact

Closure)

INPUT

2

1

 

OUTPUT

 

DC 48V

EPO

USB Port

 

External Battery

15A Output Circuit Breaker

 

 

 

Network Surge

Cabinet Connector

Voltage Configuration

for Receptacles #5 & #6

Protection

 

20A Output Circuit Breaker

DIP Switch

 

Receptacles #1 and #2

5

Page 9
Image 9