Figure 16. Remote Mount Wiring Diagrams

NOTE

When using the Rosemount supplied combination cable, the signal wires for terminals 18 and 19 contain an additional shield wire. These two shield wires should be tied with the main shield wire at terminal 17 at the sensor terminal block and cut back to the insulation in the transmitter junction box. See Figure 17.

Figure 17. Combination Coil and Signal Cable Wiring Diagram

Coil Drive Cable

Signal Cable

Transsmiter

Cut Shield

1 Red 2 Green 3 Shield

17 Shield 18 Black 19 White

Tube

1 Red 2 Green 3 Shield

17 Shield 18 Black 19 White