Quick Installation Guide

Rosemount 8712 / 8700 Series

00825-0100-4664, Rev BB January 2013

Table 12. Electrical Data

Rosemount 8705 and 8711 Sensors

 

 

 

 

Coil excitation circuit:

40 V DC (pulsed), 0,5 A, 20 W maximum

 

 

 

Electrode circuit:

in type of explosion protection intrinsic safety EEx ia IIC, Ui

= 5 V, li = 0.2 mA,

 

 

Pi = 1 mW, Um = 250 V

 

 

 

 

Table 13. Relation between ambient temperature, process temperature, and temperature class(1)

 

 

 

Maximum Process

 

Temperature

Meter Size (Inches)

 

Maximum Ambient Temperature

Temperature

 

Class

1/2

 

115 °F (65 °C)

239 °F (115 °C)

 

T3

1

 

149 °F (65 °C)

248

°F (120 °C)

 

T3

1

 

95 °F (35 °C)

95

°F (35 °C)

 

T4

11/2

 

149 °F (65 °C)

257

°F (125 °C)

 

T3

11/2

 

122 °F (50 °C)

148 °F (60 °C)

 

T4

2

 

149 °F (65 °C)

257

°F (125 °C)

 

T3

2

 

149 °F (65 °C)

167 °F (75 °C)

 

T4

2

 

104 °F (40 °C)

104 °F (40 °C)

 

T5

3 - 36

 

149 °F (65 °C)

266

°F (130 °C)

 

T3

3 - 36

 

149 °F (65 °C)

194 °F (90 °C)

 

T4

3 - 36

 

131 °F (55 °C)

131 °F (55 °C)

 

T5

3 - 36

 

104 °F (40 °C)

104 °F (40 °C)

 

T6

6

 

115 °F (65 °C)

275 °F(135 °C)

 

T3

6

 

115 °F (65 °C)

230 °F (110 °C)

 

T4

6

 

115 °F (65 °C)

167 °F (75 °C)

 

T5

6

 

140 °F (60 °C)

140 °F (60 °C)

 

T6

8-60

 

115 °F (65 °C)

284

°F (140 °C)

 

T3

8-60

 

115 °F (65 °C)

239 °F (115 °C)

 

T4

8-60

 

115 °F (65 °C)

176 °F (80 °C)

 

T5

8-60

 

115 °F (65 °C)

145 °F (65 °C)

 

T6

(1)This table is applicable for KD approval codes only.

30

Page 30
Image 30
Emerson 8712E manual Rosemount 8705 and 8711 Sensors, Maximum Process, Meter Size Inches Maximum Ambient Temperature