Installation Drawings

Figure 3 Two-Breaker Maintenance Bypass Cabinet, two-input, attached

MBB

FBO

BFB

Two Breaker Maintenance Bypass Cabinet

I

MIB

 

Critical

Load

Load Bank

(FBO)

FBO

CB1

 

DC Bus

 

CB2

Main Input

 

 

N

Switchgear

 

 

MBJ

 

UPS Module

 

EG

 

Battery

 

MIB - Maintenance Isolation Breaker

 

 

BIB - Bypass Input Breaker

 

System

MBD

 

MBB - Maintenance Bypass Breaker

 

 

 

FBO – Furnished By Others

 

 

 

N – Neutral

 

 

 

EG – Equipment Ground

 

 

 

MBJ – Main Bonding Jumper(3-wire

 

 

 

I - Option Interlock

systems only)

Figure 4 Two-Breaker Maintenance Bypass Cabinet, three-input, attached or detached

Two Breaker Maintenance Bypass Cabinet

FBO

 

MBB

 

Critical

 

 

 

 

 

 

 

 

Load

 

 

 

I

MIB

 

 

 

 

Load Bank

 

 

 

 

(FBO)

 

BFB

 

 

 

FBO

 

 

 

 

 

 

 

DC Bus

 

FBO

CB1

 

CB2

 

Main Input

 

 

N

 

 

 

MBJ

 

Switchgear

UPS Module

 

 

 

EG

 

 

 

 

 

Battery

 

MIB - Maintenance Isolation Breaker

 

 

BIB - Bypass Input Breaker

 

 

System

MBD

 

 

MBB - Maintenance Bypass Breaker

 

 

 

FBO – Furnished By Others

 

 

 

 

N – Neutral

 

 

 

 

EG – Equipment Ground

 

 

 

 

MBJ – Main Bonding Jumper(3-wire systems only)

 

 

 

I - Option Interlock

 

8

Page 12
Image 12
Emerson UPS Systems installation manual Two-Breaker Maintenance Bypass Cabinet, two-input, attached