INSTALLATION (continued)

INSTALLATION (continued)

Flush Mount Mantel Installation (Figure 11)

Note: For finishing to top of fireplace, refer to Figure 13.

The fireplace must extend 3/4" beyond finished wall surface when

 

using a flush mount mantel. Refer to Figure 11 to locate nailing

 

flanges on fireplace sides. Mark and drill two (2) 1/8" holes into

 

fireplace side to mount each nailing flange. Use eight (8) 1/2"

 

hex-head screws supplied in hardware package to attach nailing

 

flanges to fireplace sides.

 

NAIL OR OTHER SUITABLE FASTENER

Figure 11

Attention: When fireplace is installed in optional full cabinet mantel or corner mantel the (4) four nailing flanges shown in Figure 11 will not be installed on the side of outer casing. The fireplace will be attached to the full cabinet mantel or corner mantel with the (2) two nailing flanges located on the top of the outer casing assembly.

Framing (Figure 12)

Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall covering and fireplace facing material. The fireplace framing should be constructed of 2 x 4 lumber or heavier. The framing headers may rest on the fireplace standoffs. Refer to Figure 12 for minimum framing dimensions.

CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS, AND WALL COVERING DETAILS BEFORE FRAMING CONSTRUCTION BEGINS.

Framing dimension "A" includes a three inch clearance for standoffs on firebox. After installing firebox into framing, the finished wall surface must cover the three inch opening above the firebox.

 

DVD32

DVD36

DVD42

DVD48

 

 

 

 

 

"A"

35 3/4"

35 3/4"

37 3/4"

37 3/4"

 

(908 mm)

(908 mm)

(959 mm)

(959 mm)

"B"

34 3/8"

37 3/8"

43 3/8"

49 3/8"

 

(873 mm)

(949 mm)

(1102 mm)

(1254 mm)

"C"

16 3/8"

16 3/8"

16 3/8"

16 3/8"

 

(416 mm)

(416 mm)

(416 mm)

(416 mm)

Figure 12

Attention: Add 3-3/4" to “A” dimensions when using a flush mantel base.

Attention: If a base or mantel is not used and the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, it shall be installed on a metal or wood panel extending the full width and depth of the appliance. The vertical dimension in Figure 12 must be adjusted when a metal or wood panel is placed beneath the appliance.

Finishing (Figures 13 and 14)

Finish the walls with the material of your choice. Figure 3 on page 9 shows the minimum vertical and corresponding maximum horizontal dimensions of mantels or other combustible projections above the top front edge of the fireplace.

Only non-combustible materials may be used to cover the black fireplace front.

Warning: When finishing the fireplace never obstruct or modify the air inlet/outlet louvers in any manner. Provide adequate clearances around air openings into the combustion chamber.

Caution: If the joints between the finished wall and the fireplace surround (top and sides) are sealed, a 300°F minimum sealant material must be used. These joints are not required to be sealed. Only non-combustible material (using 300°F minimum adhesive if needed), can be applied as facing to the fireplace surround.