Follow correct option according to venting method.
Connecting Directly to Fireplace
If the air inlet and flue outlet tubes are to be connected directly to the unit (no rigid venting system is being used), then the gasket provided must be used to seal the 4” (102 mm) flue outlet tube. Peel the paper off the
|
| PARTS LIST | |
INDEX | PART |
| DESCRIPTION |
NUMBER | NUMBER |
| |
1 | DV769 |
| Vent Cap Assembly |
2 | 19193 |
| Outside Mounting Plate |
3 | 19194 |
| Air Inlet Tube |
4 | DV524 |
| Flue Outlet Tube |
5 | 19196 |
| Firestop/Thimble Assembly |
6 | 20527 |
| Gasket |
Connecting to Rigid Vent System
If the air inlet and flue outlet tubes are to be connected to a rigid venting system (and not directly to the back of the unit), then do not use the gasket provided. High temperature sealant should be applied to the outside of the 4” diameter (102 mm) flue outlet tube (if tube was cut, it is recommended to use cut end) and to the in- side of the tube on the end that connects to the vent cap. Continue with step 13.