Empire Comfort Systems 3)(N, 1, 2 INSTALLATION continued, Flush Wall Installation, Figure Figure

Models: 2 1 DVD32FP3 3)(N

1 60
Download 60 pages 21.3 Kb
Page 15
Image 15
Flush Wall Installation

INSTALLATION (continued)

Flush Wall Installation

FINISHED WALL

3! OF NON-COMBUSTIBLE MATERIAL

FRONT TRIM OR NON- COMBUSTIBLE MA TERIAL (INSTALLA TION IS OPTIONAL)

JOINT BETWEEN FINISHED

WALL AND UNIT SEALED

WITH 300° F, 149° C SEALANT

MATERIAL (SEALANT IS OPTIONAL)

Figure 13

Combustible Surround Installation

Attention: Cold climate installation recommendation: When installing this unit against a non-insulated exterior wall, it is recommended that the outer walls be insulated to conform to applicable insulation codes.

Vent Runs (Figures 15, 16, 17, 18 and 19)

In planning the installation for the fireplace, it is necessary to install certain components before the appliance is completely positioned and installed.These include the direct vent system, gas piping for the appliance and the electrical wiring. (If the fan option is used.)

The appliance can be mounted on any of the following surfaces:

1.A flat, hard combustible (burnable) surface.

2.A raised wooden platform.

3.Four (4) corner supports. (Example: Four (4) concrete masonry blocks.) These supports must be positioned so they contact all four (4) perimeter edges on the bottom of the unit.

VERTICAL, 90° ELBOW WITH HORIZONTAL

TERMINATION

2 X 4 HEADER

STAND OFF

MANTELSHELF

COMBUSTIBLE SURROUND

FINISHED WALL

3! OF NON-COMBUSTIBLE MATERIAL FRONT TRIM OR NON-COMBUSTIBLE MATERIAL (INSTALLATION IS OPTIONAL)

JOINT BETWEEN FINISHED WALL AND UNIT SEALED WITH 300° F 149° C SEALANT MATERIAL (SEALANT IS OPTIONAL)

DVD32, 36

47½

(121 cm)

TO BOTTOM

OF UNIT

DVD42, 48 49 ½(126 cm)

TO BOTTOM

OF UNIT

VENTCAP/ THIMBLE

Figure 15

Figure 14

23552-4-0408

Page 15

Page 15
Image 15