Cutting the Hole (Figures 24)

VENTING FIREPLACE - TOP (continued)

D

C

B

V

H

C

B

A

CENTER OF ELBOW

STRAIGHT OUT

(MINIMUM)

Cutting the Hole (Figures 24)

After the fireplace has been positioned in its permanent location, the hole through the exterior wall of the house can be cut. This hole must be 10" (254mm) high x 10" (254mm) wide with its center line determined by the amount of vertical rise and horizontal run of the termination. (See Figure 24) When locating the hole it must be noted that the bottom of the cap must be 12" (305mm) above the ground level, and top of the cap must be no less than 18" (457mm) below a combustible projection, and no closer than 9" (229mm) to any wall running parallel to vent termination. (See Figure 25)

FIREPLACE

HARD ELBOW DIMENSIONS

 

SERIES

"A"

"B"

"C"

"D"

DVD32FP

41-1/2"

4"

6"

9

1/8"

 

(1054 mm)

(102 mm)

(152 mm)

(232 mm)

DVD36FP

41-1/2"

4"

6"

9

1/8"

 

(1054 mm)

(102 mm)

(152 mm)

(232 mm)

DVD42FP

43-1/2"

4"

6"

9

1/8"

 

(1105 mm)

(102 mm)

(152 mm)

(232 mm)

DVD48FP

43-1/2"

4"

6"

9

1/8"

 

(1105 mm)

(102 mm)

(152 mm)

(232 mm)

FIREPLACE

FLEX PIPE 90 DEGREE BEND

SERIES

"A"

"B"

"C"

"D"

DVD32FP

43"

4-1/2"

6-1/2"

9 1/8"

 

(1092 mm)

(114 mm)

(165 mm)

(232 mm)

DVD36FP

43"

4-1/2"

6-1/2"

9 1/8"

 

(1092 mm)

(114 mm)

(165 mm)

(232 mm)

DVD42FP

45"

4-1/2"

6-1/2"

9 1/8"

 

(1143 mm)

(114 mm)

(165 mm)

(232 mm)

DVD48FP

45"

4-1/2"

6-1/2"

9 1/8"

 

(1143 mm)

(114 mm)

(165 mm)

(232 mm)

MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE

SEE FIGURE 20 ON PAGE 18 FOR PERMISSIBLE "H" AND "V"

DIMENSIONS.

Figure 24

Positioning the Fireplace

Determine the exact position of the appliance so the direct vent termination will be centered (if possible) between two (2) studs.This will avoid any extra framing.All vent kit pipes should be assembled on the unit after the unit is moved into the final position.

minimum

Figure 25

MAXIMUM HORIZONTAL

RUN WITH NO VERTICAL

RISE AND 90° ELBOW

MAXIMUM HORIZONTAL RUN WITH MINIMUM VERTICAL RISE AND 90° ELBOW

Figure 26

Page 20

23552-4-0408