Maxitrol Valve Conversion

DIRECT IGNITION PROPANE/LP GAS CONVERSION

Maxitrol Valve Conversion

 

 

 

 

“A”

 

 

 

 

 

 

 

 

 

 

 

 

Model

AIR SHUTTER

BURNER ORIFICE

 

 

SETTINGS

 

 

 

Opening "A"

Propane/LP Orifice

 

DVD32

1/4" (6.4 mm)

#56

 

DVD36

1/4" (6.4 mm)

#55

REGULATOR FITTING

DVD42

5/16" (7.9 mm)

1.45 mm

NOTE: STAMPED WITH

DVD48

5/16" (7.9 mm)

#52

GAS TYPE SET FOR USE

 

Figure 62