Empire Comfort Systems CIBV-30-20 installation instructions Cleaning, Blower Motor, Wiring

Models: CIBV-30-20

1 28
Download 28 pages 38.11 Kb
Page 27
Image 27
Cleaning

Cleaning

The blower wheel will collect lint and could require cleaning once a year. If the air output decreases or the noise level increases, it indicates a dirty wheel.

Blower Motor

The blower motor does not have oiling holes. Do not attempt to oil blower motor.

Wiring

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. For an ungrounded receptacle, an adapter, which has two prongs and a wire for grounding, can be purchased, plugged into the ungrounded receptacle and its wire connected to the receptacle mounting screws. With this wire completing the ground, the appliance cord plug can be plugged into the adapter and be electrically grounded.

CAUTION:Labelallwirespriortodisconnectionwhenservicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING:

Unplugging of blower accessory will not stop the heater from cycling. To shut heater off: Turn temperature dial or thermostat to lowest setting. Turn knob on gas control to "OFF", depressing slightly. Do not force.

PARTS LIST

Index Part

No. No. Description

1R-1454 Brass Bushing (4 Required)

2R-1499 Rubber Grommet (4 Required)

3CI-002 Blower Housing

4R-1517 Tinnerman Clip (4 Required)

5R-2804-A Blower Assembly

6CI-003 Blower Housing Cover

7

R-2099

Cord Set

8R-3767-A Wire Harness

9A

CI-004

Fan Control Bracket

 

 

(Use with CIBV-30 and CIVF-25)

9B

CI-325

Fan Control Bracket

 

 

(Use with CIDV-30)

10

R-2503

Fan Control

11R-2805 Auto/Off/On Switch

12CI-220 Fan Control Shield (Use with CIVF-25)

13R-1410 Bushing 7/8" Diameter

15627-5-0807