INTRODUCTION

INTRODUCTION

Introduction

Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented fireplace heater.

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner fill out and mail warranty card supplied with heater.

3.Installer should show owner how to start and operate heater and thermostat.

General Information

This appliance is design certified in accordance with American National Standard /CSA Standard ANSI Z21.88 and CSA 2.33 by the Canadian Standards Association, as a Vented Fireplace Heater and must be installed according to these instructions.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

Important

All correspondence should refer to complete Model Number, Serial Number and type of gas.

Notice: During initial firing of this unit, its paint will bake out and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ NFPA 54.*

*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.

High Altitudes

When installing this unit at an elevation above 2000 feet (in the United States) it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Generally, input should be reduced 4 percent for each 1000 feet above sea level. However, if the heating value of the gas has been reduced, this general rule may not apply. Check with local gas utility for proper orifice size identification.

APPLIES TO CANADIAN MODELS ONLY FOR PROPANE GAS.

Altitude: 0-4,500 feet (0-1370 m) without orifice change.

APPLIESTO CANADIAN MODELS ONLYFOR NATURAL GAS.

Altitude 0-2,000 feet (0-610m) without orifice change.

Cet appareil est équipé pour des altitudes compris entre 0 et 2000 pieds (0-610m) seulement.

For installations from 610-1370 metres (2,000-4,500 ft.) the orifice size (DMS) for natural gas is 39. See data plate for additional information.

For high altitude installations consult the local gas distributor or the authority having jurisdiction for proper rating methods. If the installer must convert the unit to adjust for varying altitudes, the information sticker (illustrated below) must be filled out by the installer and adhered to the appliance at the time of conversion.

THE CONVERSION SHALL BE CARRIED OUT BY A MAN- UFACTURER'S AUTHORIZED REPRESENTATIVE IN AC- CORDANCE WITH THE REQUIREMENTS OF THE MANU- FACTURER,PROVINCIALORTERRITORIALAUTHORITIES HAVING JURISDICTIONAND INACCORDANCEWITHTHE REQUIREMENTS OF THE CAN/CGA-B141.1 OR CAN/CGA- B141.2 INSTALLATION CODES.

LA CONVERSION DOIT ÊTRE EFFECTUÉE CONFOR- MÉMENT AUX RÉGLEMENTATION PROVINCIAUX EN CAUSE ETAUX EXIGENCES DES CODES D'INSTALLATION CAN/CGA-B149.

This appliance has been converted for use at an altitude of

Orifice size

 

 

 

 

Manifold Pressure

 

Input (Btu/h)

 

 

 

Fuel Type

 

 

 

Date of Conversion

 

 

Converted by

 

 

Cet appareil a été converti au

InjecteurPression à la tubulure d'alimentation Déoit calorifique

15627-5-0807