Wiring Diagram (Figure 21)

Figure 21

MAINTENANCE

IMPORTANT: Turn off gas before servicing appliance. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season.

Clean Burner and Control Compartment

Keep the control compartment, logs and burner area surrounding the logs clean by vacuuming or brushing at least twice a year. Cleaning Procedure (Figure 22)

1.Turn off pilot light at gas valve.

2.Remove screen front. [(2) 10 x 1/2" screws]

3.Vacuum burner compartment especially around orifice/ primary air openings.

4.Replace screen front. [(2) 10 x 1/2" screws]

5.Ignite pilot. (See Lighting Instructions, page 15)

6.Operate the main burner and visually check to make sure the flame pattern appears similar to the pictorial illustration shown for proper main burner flame pattern, Figure 18. If it appears abnormal call a service person.

Verify proper operation after servicing.