25613-0-0309Page 12
Flush Wall Installation
Figure 12
Combustible Surround Installation
Figure 13
Vent Runs (Figures 14, 15, and 16)
In planning the installation for the replace, it is necessary to install
certain components before the appliance is completely positioned
and installed. These include the direct vent system, gas piping for
the appliance and the electrical wiring.
The appliance can be mounted on any of the following surfaces:
1. A at, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact all
four (4) perimeter edges on the bottom of the unit.
VERTICAL, 90° ELBOW WITH HORIZONTAL
TERMINATION
Figure 14
FINISHEDWALL
JOINTBETWEEN FINISHED
WALL AND UNIT SEALED
WITH300° F, 149°CSEALANT
MATERIAL(SEALANTISOPTIONAL)
6”OF NON-COMBUSTIBLE MATERIAL
NON-COMBUSTIBLEMATERIAL
(INSTALLATIONIS OPTIONAL
FINISHEDWA LL
COMBUSTIBLESURROUND
MANTELSHELF
2X4
HEADER
STANDOFF
6”OF NON-COMBUSTIBLE
MATERIAL
FRONTTRIM OR
NON-COMBUSTIBLE
MATERIAL(INSTALLATION
ISOPTIONAL)
JOINTBETWEEN FINISHED
WALLAND UNIT SEALED WITH
300°F(149°C) SEALANT MATERIAL
(SEALANTIS OPTIONAL)
Attention: Cold climate installation recommendation:
When installing this unit against a non-insulated exterior
wall, it is recommended that the outer walls be insulated to
conform to applicable insulation codes.
3”(76mm)
MINIMUMCLEARANCE
TOCOMBUSTIBLES
VENTCAP/
THIMBLE
WALLFIRESTOP
DVX36,42
501/2” (1283mm)
TOBOTTOM
OFUNIT