25613-0-0309 Page 7

Figure 1

LEFTSIDE VIEW FRONTVIEW
RIGHTSIDE VIEW
ELECTRICAL
ACCESS
VENTCOLLAR
TOPVIEW
GASLINE ACCESS
A
C
J
G
I
GASLINE
ACCESS
H
D
E
B
VENTCOLLAR
STANDOFFS
NAILING
FLANGES
GLASS
FRAME
ASSEMBLY
GASLINE
ACCESS
RATINGPLATE
ANDLABELS
GASCONTROLS
ANDSWITCHES

Remote Control Options

& Accessories

Description

FRBC Millivolt Battery Remote ON/OFF

FRBTC Millivolt Battery Remote Thermostat

TRW Millivolt WIRELESS Wall Thermostat

TMV Millivolt REED SWITCH Wall Thermostat

FWS-1 Millivolt Wall Switch

FREC Electric Remote

FBB4 Complete Blower Assembly (IP Only)

NOTE: Air shutter settings are factory minimum settings. Some venting congurations may require minor air shutter adjustments for

optimum performance.

SPECIFICATIONSFIREPLACE DIMENSIONS
DVX36 NAT DVX36 LP DVX42 NAT DVX42 LP
Input Btu/hr Maximum 35,000 30,000 37,500 35,000
Btu/hr Minimum 24,000 21,000 26,000 24,000
KWH (Maximum) 10.3 8.8 11.0 10.3
(Minimum) 7.2 6.2 7.6 7.2
Orice #32 (P-211) 1.65 mm (P-250) #31 (P-209) #50 (P-245)
Air Shutter Opening 1/4"(6.4 mm) FULL OPEN 1/4" (6.4 mm) FULL OPEN
Height without standoff 34 3/4 (3.2 mm) 34 3/4" (3.2 mm) 34 3/4" (3.2 mm) 34 3/4" (3.2 mm)
Width 39 3/8" (1,000 mm) 39 3/8" (1,000 mm) 43 3/8" (1,101 mm) 43 3/8" (1,101 mm)
Depth 19 7/8" (505 mm) 19 7/8" (505 mm) 19 7/8" (505 mm) 19 7/8" (505 mm)
Gas Inlet Shutoff Valve (Pipe) 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT
DVX Dimensions
Dimension DVX36FP DVX42FP
A34 3/4"
882.7 mm
34 3/4"
882.7 mm
B39"
990.6 mm
43"
1092.2 mm
C19 7/8"
505 mm
19 7/8"
505 mm
D25"
635 mm
25"
635 mm
E36"
914.4 mm
40"
1016 mm
G26 1/2"
673.1 mm
26 1/2"
673.1 mm
H40 3/4"
1035.1 mm
40 3/4"
1035.1 mm
I13 1/4"
336.6 mm
13 1/4"
336.6 mm
J7 1/8"
181 mm
7 1/8"
181 mm