25613-0-0309Page 8
Mantel Chart (Figure 3)
Figure 3
Clearances (Figure 4)
Clearance from top front edge of replace to ceiling is 36"
Clearance from side of replace to adjacent sidewall is 6".
36”
(914mm)
6”(152mm)
Figure 4
Figure 5
Note: Island (C) and Room Divider (F)
installation is possible as long as the
horizontal portion of the vent system
(H) does not exceed 20 feet with a
minimum vertical run of 8 feet. See
details in Venting Section.
When you install your Direct Vent
Fireplace in (F) Room divider or (A) Flat
on wall corner positions, a minimum of
6 inches clearance must be maintained
from the perpendicular wall and the
front edge of the appliance.
Figure 2
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the replace. The ow of heat can
ignite combustibles.
(A)CORNER
INSTALLATION
(E)ANGLED CORNER
INSTALLATION
(C)ISLAND
INSTALLATION
(B)CABINET
INSTALLATION
(F)ROOM DIVIDER
INSTALLATION
(D)FLUSH WALL
INSTALLATION
Clearance to Combustibles
Back 0" (0 mm)
Side 0" (0 mm)
Floor 0" (0 mm)
Top Stand-off 0" (0 mm)
Top Framing Edge 6" (152 mm)
GLASSFRONT
6”
SEEMANTLE CHART FOR
MAXIMUMMANTLE DEPTH
2”x4”HEADER
STANDOFF
6”(152mm) HEIGHT
ABOVETOPOF
FIREPLACE
NAILING
FLANGES
TOPFRAMING
LEDGE
NON-COMBUSTIBLE
FIRST6” (SEE
MAGNIFIEDVIEW)
FINISHEDWALL
(COMBUSTIBLE)
SEEMANTLE CHART
FORMINIMUM HEIGHT
OFMANTLE ABOVE UNIT
CLEARANCESLOCATING FIREPLACE
MANTEL
19”
183/4”
17”16”
15”14”
13”12” 1110”
21/4”
11/2”
3/4”
8”
6”
41/2”
33/4”
3”
12”(305mm)
10”(254mm)
TOPEDGEOFFIREPLACE
COMBUSTIBLETRIMAND
MANTELSALLOWEDIN
SHADEDAREA